TASK 70-11-08-200-502 The Test And Control Of The Solutions Used To Etch Titanium Alloys

DMC:V2500-00-70-11-08-00A-300A-D|Issue No:003.00|Issue Date:2019-08-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 70-11-08-200-502 The Test And Control Of The Solutions Used To Etch Titanium Alloys

Introduction

The purpose of this TASK is to give details for the test and control of the solutions which can be used on titanium parts to prepare them for inspection.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

WARNING

IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIAL SAFETY INFORMATION (SUCH AS HAZARDOUS INGREDIENTS; PHYSICAL/CHEMICAL CHARACTERISTICS; FIRE, EXPLOSION, REACTIVITY, AND HEALTH HAZARD DATA; PRECAUTIONS FOR SAFE HANDLING; AND USE AND CONTROL MEASURES), AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.

Procedure

    1. SUBTASK 70-11-08-200-001 The Test and Control of Hydrofluoric Acid/Ferric Sulfate Solution

    2. This subtask is deleted.

    1. SUBTASK 70-11-08-200-002 The Test and Control of Hydrofluoric Acid/Nitric Acid Etch Solution

    2. Analysis control is unnecessary; discard the solution when it no longer produces a satisfactory etch.

    1. SUBTASK 70-11-08-200-003 The Test and Control of Nitric Acid/Hydrofluorosilicic Acid Solution

    2. This subtask is deleted.

    1. SUBTASK 70-11-08-200-004 The Test and Control of Nitric Acid/Potassium Fluoride Solution

    2. This subtask is deleted.

    1. SUBTASK 70-11-08-200-005 The Test and Control of Hydrofluoric Acid/Nitric Acid Desmutting Solution

    2. Analysis control is unnecessary, discard the solution when it no longer removes smut.

    1. SUBTASK 70-11-08-200-006 The Test and Control of Titanium Etch Neutralizing Solution

      1. Do one of the procedures in the subsequent list to do the maintenance of the swab etch solution:

        1. Procedure 1.

        2. Do a check of the solution pH before you use the solution. If the solution pH is less than 8.5, discard the solution.

        1. Procedure 2.

        2. Make and use a new solution each work shift or day you do SPM TASK 70-11-08-300-503 and discard the solution at the end of the work shift or day.

Requirements After Job Completion

Follow-On Conditions

NONE
Change Type:

Update task per procedures Rolls-Royce OP 133 and OP 148 and clarify the neutralizing solution control requirements (CAS-38522-H4T6T8) (REA19VC136)