TASK 70-11-51-200-502 Test And Control Of The Solution For Demineralized Water Washing

DMC:V2500-00-70-11-51-00A-300A-D|Issue No:001.00|Issue Date:2013-03-20

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Description

  1. TASK 70-11-51-200-502 Test And Control Of The Solution For Demineralized Water Washing

    1. General

      1. The demineralized water is tested continually, during the processing of parts. Whenever the conductivity is greater than 20 micro siemens cm.sq, the demineralized water must be changed.

      2. The conductivity meter must be calibrated annually, in accordance with in-house procedures, using appropriate conductivity standards.