DMC:V2500-00-70-11-57-00A-251A-DIssue No:002.00Issue Date:2019-08-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-11-57-110-501 The Procedure To Clean Contact Points And Wiring Harness
To identify the consumable materials, refer to the Consumable Materials Index.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-410 ISOPROPYL ALCOHOL, REAGENT GRADE | 0AL61 | CoMat 01-410 | ||
| CoMat 01-489 DIELECTRIC SOLVENT | 0WU71 | CoMat 01-489 | ||
| CoMat 01-490 CLEANER SOLVENT | 05867 | CoMat 01-490 | ||
| CoMat 01-492 CLEANER SOLVENT | 023V4 | CoMat 01-492 | ||
| CoMat 01-493 CLEANER SOLVENT | 86938 | CoMat 01-493 | ||
| CoMat 01-494 CLEANER SOLVENT | 86938 | CoMat 01-494 | ||
| CoMat 01-585 CLEANER SOLVENT | 023V4 | CoMat 01-585 | ||
| DELETED | LOCAL | DELETED | CoMat 01-491 | |
| DELETED | LOCAL | DELETED | CoMat 01-495 | |
| DELETED | LOCAL | DELETED | CoMat 01-496 |
Spares
NONESafety Requirements
WARNING
IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURERS MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS INFORMATION (SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS; FIRE, EXPLOSION, REACTIVITY, AND HEALTH HAZARD DATA; PRECAUTIONS FOR SAFE HANDLING; AND, USE AND CONTROL MEASURES) AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATIONS.