Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Description
TASK 70-80-00-990-501 General Measuring And Test Equipment Calibration Schedule
General
The schedule that follows contains suggested time elements for monitoring the accuracy of various types of measuring and test equipment used during engine inspection, test, repair and assembly.
NOTE
It is expected that individual departments or designated shop areas will adjust these time elements as necessary to closely correspond to actual use. Where a time element has not been determined, it is suggested to use the initial manufacturer recommendation as a base line.Table 1. Tools
Time Elements
Snap Gages (Special or Adjustable)
78 weeks
Alignment Gages (Progressive Plug Type)
52 to 78 weeks
Mounting Distance Gages
37 weeks
Spacer Calculation Gages
104 weeks
Flatness Checking Gages
52 weeks
Stretch Gages
52 weeks
Special Size Blocks used as Width Gages
104 weeks
Flushpin Gages or Depth Gages
78 weeks
Reaming Fixtures
24 to 52 weeks
Drilling Fixtures
24 to 52 weeks
Spline Rings
104 weeks
Runout Fixtures
8 weeks
Size Block Set
12 months
Torque Wrenches Set Type
39 weeks
Torque Wrenches Nonset Type
39 weeks
Hydraulic Wrenches
39 weeks
Cylinder Plugs
104 weeks
Thread Plugs
13 weeks
Setting Rings
78 weeks
Setting Disks
78 weeks
Engine Weight and Flow Calibration Weight Scales
5 weeks
"Last Word" Type Dial Indicators
39 weeks
All Other Dial Indicators
39 weeks
Horizontal Balancing Fixtures, Hubs, Pulleys and Auxiliaries
26 weeks
Vertical Balancing Fixtures and Auxiliaries (Except Peg Plates)
6 months
Vertical Balancing Fixture Peg Plates
64 weeks
Balancing Machine Test Weights
98 weeks
Dowel or Stud Height Tools (Not Copper Flashed)
260 weeks
Catalog Equipment (such as Micrometers, Verniers, Radius Gages, Steel Measuring Tapes etc.)
39 to 260 weeks
All Final Dimension Tools, Fixtures and Gages which are not listed above
4 weeks
CMM Automated Inspection Machine
19 weeks