EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 71-51-42-100-301 EEC Fan Harness And Ignition Supply Harness - Clean The Harness, Cleaning-001
Effectivity
FIG/ITEM | PART NO. |
|---|---|
01-005 | 740-5870-503 |
01-005 | 740-5870-505 |
01-005 | 740-5870-507 |
01-005 | 740-5870-511 |
01-005 | 740-5870-513 |
01-005 | 740-5870-9003 |
01-005 | 740-5870-9005 |
01-005 | 740-5870-9011 |
01-005 | 740-5870-9013 |
01-005 | 745-5870-501 |
01-005 | 745-5870-503 |
General
This TASK gives the procedure to clean the EEC and ignition supply harness.
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the Primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
To identify the consumable materials refer to the PCI.
References
Refer to SPM TASK 70-10-00-100-501, Cleaning - General Information.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-076 METHYL ETHYL KETONE | LOCAL | CoMat 01-076 | ||
| CoMat 02-099 LINT-FREE CLOTH | LOCAL | CoMat 02-099 | ||
| CoMat 02-102 BRUSH, PAINT | LOCAL | CoMat 02-102 |
Spares
NONESafety Requirements
NONEProcedure

WARNING
PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK WHEN YOU USE THIS CLEANING AGENT. DO NOT GET THE CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. USE THE CLEANING AGENT IN A WELL VENTILATED AREA. DO NOT BREATHE THE GAS. IF YOU GET THE CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
WARNING
BE CAREFUL WHEN YOU USE COMPRESSED AIR. PUT ON PROTECTIVE CLOTHING AND GOGGLES. MAKE SURE THAT ALL PERSONS ARE AT A SAFE DISTANCE.Remove any marking tape from the EEC and ignition harness.
Wipe the surface of the EEC and ignition harness cables
Clean the terminal ends of the EEC and ignition harness
Use clean dry compressed air.
Remove the cleaning agent and make the EEC and ignition harness dry
SUBTASK 71-51-42-110-051 Clean the EEC and Ignition Supply Harness