EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 71-52-44-700-301 EEC Link Core Harness - Test The Harness, Testing-001
General
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Megger | LOCAL | Megger | 500 volts DC or equivalent | |
| Lamp and battery teter | LOCAL | Lamp and battery tester | 4.5 volts |
Consumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Accept cable circuits where the test lamp comes on.
Reject all circuits where the test lamp does not come on.
Lightly bend or pull the cable.
Reject the cable if the lamp goes out.
NOTE
Various methods can be used for continuity testing but in all cases the maximum voltage allowed is 24 volts DCConnect the Lamp and battery teter - 4.5 volts DC to each end of the cable circuit.
SUBTASK 71-52-44-750-054 Do the Test for Continuity of EEC Link Harness-Core (Refer to Table 1)
Reject resistances less than in Step.
Lightly pull or bend the cable. Make sure the resistances do not become less than 20 megohms.
Table 2. CONNECTOR AND CONTACT NUMBERS Connector
Contact to
Connector
Contact
PRE SB 75-0081
4006VC
6
4024KS
B (Al, green)
4006VC
7
4024KS
B (Cr, white)
4006VC
8
4024KS
A (Al, green)
4006VC
9
4024KS
A (Cr, white)
4006VC
5
4025KS
E
4006VC
4
4025KS
D
4006VC
3
4025KS
B
4006VC
10
4025KS
A
SB 75-0081
4006VC
6
4024KS
B (Al, green)
4006VC
7
4024KS
B (Cr, white)
4006VC
8
4024KS
A (Al, green)
4006VC
9
4024KS
A (Cr, white)
Connect the Megger between each contact and all the other contacts within the connectors.
SUBTASK 71-52-44-750-055 Do the Test for Insulation Resistance Values of the EEC Link Harness-Core (Refer to Table 1)