TASK 71-73-48-700-101 Drain Tubes - Do a Test, Testing-001

DMC:V2500-A0-71-73-4800-00A-362A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 71-73-48-700-101 Drain Tubes - Do a Test, Testing-001

Effectivity

FIG/ITEM

PART NO.

03-100

740-5265-505

03-500

740-5267-505

02-100

740-5696-505

01-500

740-5698-505

01-100

740-5704-505

02-500

740-5792-513

General

Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service-bulletin alpha-variants refer to the IPC.

The oil, hydraulic and water drain tubes must be cleaned and inspected before this pressure test, Refer to Cleaning-000 TASK 71-73-48-100-100 and Inspection/Check-000 TASK 71-73-48-200-100.

The Test Equipment Specification

To do the test on the oil, hydraulic and water drain tubes use equipment equivalent to that shown in Figure.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NameManufacturerPart Number / IdentificationQuantityRemark
Pneumatic pressure testing rigLOCALPneumatic pressure testing rig
MS21913-4 Blanking plug0AM53MS21913-4
MS21913-5 Blanking plug0AM53MS21913-5
MS21913-6 Blanking plug0AM53MS21913-6

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 71-73-48-780-051 Prepare the Tubes (01-100, 01-500, 02-100, 02-500, 03-100 and 03-500) for the Hydraulic Pressure Test

    2. Install the applicable blanking plugs to one end of the tubes (01-100, 01- 500, 02-100, 02-500, 03-100 and 03-500).

    1. SUBTASK 71-73-48-780-052 Do the Pneumatic Pressure Test on the Tubes (01-100, 01-500, 02-100, 02- 500, 03-100 and 03-500)

    2. Connect the tube to the outlet of the Pneumatic pressure testing rig.

    3. Put a pressure of 14.5 psi (100 kPa) in the tube.

    4. Put the tube in the water tank.

    5. Let the pressure stay in the tube for 1 minute.

    6. Make sure that the tube has no leaks. If the tube has leaks, reject the tube, Refer to Inspection-000 TASK 71-73-48-200-100.

    7. Decrease the pressure in the tube to zero.

    8. Disconnect the tube from the outlet of the Pneumatic pressure testing rig.

    9. Remove the blanking cap from the tube.

  1. Figure: Pneumatic Pressure Testing Rig

    Pneumatic Pressure Testing Rig

Requirements After Job Completion

Follow-On Conditions

NONE
Manufacturer Code:0AM53
Enterprise Name:IAE INTERNATIONAL AERO ENGINES AG
BU Name:NULL
Building:SUITE 400
Street:628 HEBRON AVENUE
City:GLASTONBURY
State:CT
Zip Code:06033
Country:USA
Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Manufacturer Code:0AM53
Tool Number:MS21913-4
Tool Name:MS21913-4 Blanking plug
Manufacturer Code:0AM53
Tool Number:MS21913-5
Tool Name:MS21913-5 Blanking plug
Manufacturer Code:0AM53
Tool Number:MS21913-6
Tool Name:MS21913-6 Blanking plug
Manufacturer Code:LOCAL
Tool Number:Pneumatic pressure testing rig
Tool Name:Pneumatic pressure testing rig