TASK 72-00-00-050-001 Engine General - Remove The Magnetic Chip Detectors (MCD) Probes, Removal-001

DMC:V2500-A0-72-00-0000-00A-520A-B|Issue No:001.00|Issue Date:2014-05-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-00-00-050-001 Engine General - Remove The Magnetic Chip Detectors (MCD) Probes, Removal-001

General

Discard all rubber packing removed in this procedure.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 72-00-00-050-055 Remove the Master MCD Probe at Position 1

    2. Refer to Figure and Figure.

    3. Push the Master MCD probe in to its housing and turn it counterclockwise. Pull and remove the Master MCD probe.

    4. Pre SBE 79-0042. Remove and discard the packing.

    5. SBE 79-0042. Remove and discard the sealing ring.

    1. SUBTASK 72-00-00-050-056 Remove the Remaining MCD Probes

    2. Refer to Figure and Figure.

      1. Remove the MCD probe at position 2.

      2. Push the MCD probe in to its housing and turn it counterclockwise. Pull and remove the MCD probe.

      3. Pre SBE 79-0042. Remove and discard the packing.

      4. SBE 79-0042. Remove and discard the sealing ring.

    3. Do Step and Step again for the MCD probes at positions 3 thru 7.

  1. Figure: Pre SBE 79-0042: Remove the MCD probes

    Pre SBE 79-0042: Remove the MCD probes

    Figure: SBE 79-0042: Remove the MCD probes

    SBE 79-0042: Remove the MCD probes

Requirements After Job Completion

Follow-On Conditions

NONE