Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-00-50-220-006 LPT Module - Examine The LPT Module Compartment For Leaks, Inspection-006
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| IAE 1P16354 Vacuum Test Adapter | 0AM53 | IAE 1P16354 | 1 | |
| IAE 1P17523 Blank-off Plate | 0AM53 | IAE 1P17523 | 1 | |
| IAE 6F10030 Vacuum test cart | 0AM53 | IAE 6F10030 | 1 |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 10-077 APPROVED ENGINE OILS | LOCAL | CoMat 10-077 |
Spares
NONESafety Requirements
NONEProcedure
Lubricate the bolts, nuts and washers with CoMat 10-077 APPROVED ENGINE OILS.
Install the IAE 1P16354 Vacuum Test Adapter 1 off to the No. 5 bearing outer oil scavenge tube. Figure.
Lubricate the bolts, nuts and washers with CoMat 10-077 APPROVED ENGINE OILS.
Install the IAE 1P17523 Blank-off Plate 1 off to the No. 5 bearing outer oil feed tube. Figure.
SUBTASK 72-00-50-420-385 Install the Vacuum Test Adapter and the Blank-off Plate to the Turbine Exhaust Case
Refer to Figure.
Connect the hose of the IAE 6F10030 Vacuum test cart 1 off to the nipple of the IAE 1P16354 Vacuum Test Adapter 1 off.
NOTE
Refer to the manufacturer's manual for the operation of the vacuum test cart.Attach the cart vacuum gage hose to the plug of the IAE 1P16354 Vacuum Test Adapter.
Set the air pressure at the test port to -20in Hg (-508 mm Hg gage). Based on the ambient pressure, refer to the table below for the vacuum pressure in psia.
Ambient Pressure of the Day (psia)
Vacuum Pressure (psia)
14.7
4.9
14.5
4.7
14.3
4.5
14.1
4.3
13.9
4.1
13.7
3.9
13.5
3.7
13.3
3.5
13.1
3.3
Vacuum pressure (psia) = Ambient pressure of the day (psia) - 9.8 psia
SUBTASK 72-00-50-720-052 Do an Evacuation Check for the No. 5 Bearing Compartment
Figure: Install the adapter to the No. 5 bearing outer oil scavenge tube
Install the adapter to the No. 5 bearing outer oil scavenge tube

Figure: Install the plate to the No. 5 bearing outer oil feed tube
Install the plate to the No. 5 bearing outer oil feed tube

Figure: Connect the fitting of the vacuum test cart to the adapter
Connect the fitting of the vacuum test cart to the adapter