DMC:V2500-A0-72-41-1101-00A-251A-CIssue No:002.00Issue Date:2017-08-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-41-11-100-001-A00 HPC Stage 3 - 8 Drum Disk - Clean, Cleaning-001
General
This TASK gives the procedure to clean the HP Compressor Stage 3 To 8 Disks.
The practices and processes referred to in the procedure by SPM TASK numbers are in the SPM.
Fig/item numbers in parentheses in the procedure agree with those used in the EIPC. Only the primary Fig/item numbers are used.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
WARNING
IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS. THESE CONTAIN INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.
Procedure

CAUTION
THIS PROCEDURE MUST BE FOLLOWED BY THE DEMINERALISED WATER WASH, Step.Remove the grease. Refer to SPM TASK 70-11-03-300-503.
SUBTASK 72-41-11-110-051 Remove the Grease

CAUTION
THIS PROCEDURE MUST BE FOLLOWED BY THE DEMINERALISED WATER WASH.Clean the disks. Refer to TASK 70-11-03-300-503.
SUBTASK 72-41-11-110-052 Clean the Disks
Compare the value with the value in Step.
Measure the conductivity of the demineralised water between the disks and the internal pockets.
SUBTASK 72-41-11-110-053 Wash the Disks