DMC:V2500-A0-72-41-3311-00A-920A-CIssue No:001.00Issue Date:2013-11-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-41-33-300-008 HPC Inlet Variable Stator Vane Shroud - Replace The Dowel Pins, Repair-008 (VRS6148)
General
This Repair must only be done when the instruction to do so is given in 72-41-33 Inspection/Check.
This repair is to replace worn dowel pins in the VIGV shroud assembly.
Price and availability
Refer to IAE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Standard workshop equipment | LOCAL | Standard workshop equipment | ||
| Heat protection gloves | LOCAL | Heat protection gloves |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 03-026 LIQUID NITROGEN | LOCAL | CoMat 03-026 |
Spares
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Retaining ring | AS20763 | A/R | ||
| Dowel pin | AS20744 | A/R |
Safety Requirements
NONEProcedure
Refer to Figure.
SUBTASK 72-41-33-350-072 Remove the Dowel Pins
Refer to Figure.
SUBTASK 72-41-33-220-125 Examine the Holes
Refer to Figure.
Use a suitable installation tool.
Freeze the pins with CoMat 03-026 LIQUID NITROGEN and put the pins in position.
Use heat protecting gloves.
Install the dowel pins into the half shrouds.
SUBTASK 72-41-33-350-073 Replace the Dowel Pins
Figure: Replace the dowel pins
Replace the dowel pins

Figure: Replace the dowel pins
Replace the dowel pins