TASK 72-44-20-300-036 HPT Stage 1 Vane - Replace The Covers And Baffle, Repair-036 (VRS3610)

DMC:V2500-A0-72-44-2000-01A-970A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-44-20-300-036 HPT Stage 1 Vane - Replace The Covers And Baffle, Repair-036 (VRS3610)

Effectivity

FIG/ITEM

PART NO.

01-240

2A5591

Material of component

PART IDENT

SYMBOL

MATERIAL

Stage 1 HPT Vane Assembly

-

Cobalt Alloy

Baffle Covers

-

Nickel Alloy

General

Price and availability - Refer to IAE

The practices and processes referred to in the procedure by the TASK number are in the SPM.

Repair Facilities

The Source Demonstration requirement of this repair mean that any facility mot authorized to accomplish this repair either utilize the Authorized Repair Vendors listed below or contact IAE Repair Development Group to determine if a qualification program can be initiated at their facility.

IAE International Aero Engines
AG
400 Main Street M/S
121-10
East Hartford, CT
06108
USA
Attn: Manager Maintenance Operations

Authorized repair vendors for Repair VRS3610 are listed below:

Pratt and Whitney Engine Services
North Haven Airfoil Repair Operation
415 Washington Avenue
North Haven, CT 06473
USA

Dallas Airfoil Repair Operations
(GSP-DARO)
1177 Great Southwest
Parkway N
Grand Prairie,
Texas 75050
USA
Mailstop: 970-00
Tel: (214) 647-7800
Fax: (214) 641-6974

The designation by IAE of an authorized vendor indicates that repair vendor has demonstrated the necessary capability to enable it to carry out the listed repair work. However, IAE makes no warranties or representations concerning the qualification or quality standards of the repair vendors to carry out the repair work and accepts no responsibility whatsoever for any work that may be carried out by a repair vendor, other than when IAE is listed as the repair vendor. Authorized repair vendors do not act as agents or representatives of IAE.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

Requirements After Job Completion

Follow-On Conditions

NONE