TASK 72-45-00-300-011 HPT Stage 2 Airseal - Knife-Edge, Plasma Repair, Repair- 011 (VRS3833)

DMC:V2500-A0-72-45-0012-04A-609A-C|Issue No:002.00|Issue Date:2019-02-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-45-00-300-011 HPT Stage 2 Airseal - Knife-Edge, Plasma Repair, Repair- 011 (VRS3833)

Effectivity

FIG/ITEM

PART NO.

01-080

2A4157

01-080

2A4196

01-080

2A4197

Material of component

DESCRIPTION

RR SYMBOL

MATERIAL

Stage 2 HPT Airseal

Nickel alloy

General

Price and availability - not applicable.

Preliminary Requirements

Pre-Conditions

Action/ConditionData Module/Technical Publication
Make sure that all the cleaning and inspection procedures are done before this repair.

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. Repair Facilities

    2. The source demonstration requirements of this repair means that any facility not authorized to accomplish this repair either, utilize the authorized repair vendors listed below or contact the IAE repair services group to determine if a qualification program can be initiated at their facility.

      IAE International Aero Engines AG

      400 Main Street

      M/S 121-10

      East Hartford CT 06118

      U.S.A.

      Attn: Manager Technical Services

    3. Authorized repair vendors for Repair VRS3833 are listed below:

      Pratt and Whitney Global Service Partners

      East Hartford Repair Operations (GSP-EHRO)

      400 Main Street, Well No.14 - Mail Stop 117-62

      East Hartford, CT 06118

      U.S.A.

      Tel: (860) 557-2646

      Fax: (860) 557-2647

    4. The designation by IAE of an authorized repair vendor indicates that the repair vendor has demonstrated the necessary capability to enable it to carry out the listed repair work. However, IAE makes no warranties or representations concerning the qualifications or quality standards of the repair vendors to carry out the repair work and accepts no responsibility whatsoever on any work that may be carried out by a repair vendor, other than when IAE is listed as the repair vendor. Authorized repair vendors do not act as agents or representatives of IAE

Requirements After Job Completion

Follow-On Conditions

NONE
Change Type: