Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-45-11-300-010 HPT Stage 1 Hub - Machine Repair The Hub Spacer Contact Surface, Repair-010 (VRS3191)
General
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
The Source Demonstration requirements of this repair means that any facility not authorized to accomplish this repair either utilize the Authorized Repair Vendors listed below or contact IAE Repair Development Group to determine if a qualification program can be initiated at their facility.
IAE International Aero Engines AG
c/o Rolls-Royce Deutschland Ltd und Co KG
Eschenweg 11
Dahlewitz
15827 Blankenfelde-Mahlow
Germany
ATTN: Manager Technical Services
Authorized Repair Vendors for the Machine section of Repair VRS3191 are listed below:
Pratt and Whitney Global Service Partners
East Hartford Repair Operations (GSP-EHRO)
400 Main Street, Well No.14 - Mail Stop 117-62
East Hartford, CT 06108
USA
Tel: (860) 557-2646
Fax: (860) 557-2647
Turbine Component Repair
Caval Tool Division
655 New Britain Ave
Newington, CT 06111
USA
Tel: (860) 666-8414
Fax: (860) 667-6644
MTU Maintenance GmbH
Airport Hannover
Muenchner Strasse 31
30855 Langenhagen
Germany
Tel: 49 511 7806 0
Fax: 49 511 7806 111
IHI Corporation
229 Tonogaya,
Mizuho-Machi Nishitama-Gun
Tokyo 190 -1297
Japan
Tel: 81-42-568-7362
Fax: 81-42-568-7566
ATTN: Program Manager, V2500
Authorized Repair Vendors for the Shot Peen section of Repair VRS3191 are listed below:
Pratt and Whitney Global Service Partners
East Hartford Repair Operations (GSP-EHRO)
400 Main Street, Well No.14 - Mail Stop 117-62
East Hartford, CT 06108
USA
Tel: (860) 557-2646
Fax: (860) 557-2647
Metal Improvements Company Inc. (MIC)
145 Addison Road
P. O. Box 487
Windsor, CT 06095
USA
Tel: (860) 688-6201
Fax: (860) 285-8809
MTU Maintenance GmbH
Airport Hannover
Munchner Strasse 31
D-30855 Langenhagen
Germany
Tel: 49 511 7806 0
Fax: 49 511 7806 111
IHI Corporation
229 Tonogaya,
Mizuho-Machi Nishitama-Gun
Tokyo 190-1297
Japan
Tel: 81-42-568-7362
Fax: 81-42-568-7566
ATTN: Program Manager, V2500
The designation by IAE of an authorized repair vendor indicates that the repair vendor has demonstrated the necessary capability to enable it to carry out the listed repair work. However, IAE makes no warranties or representations concerning the qualifications or quality standards of the repair vendors to carry out the repair work, and accepts no responsibility whatsoever for any work that may be carried out by a repair vendor, other than when IAE is listed as the repair vendor. Authorized repair vendors do not act as agents or representatives of IAE.
Repair Facilities
Figure: Repair Details and Dimensions
Sheet 1

Figure: Repair Details and Dimensions
Sheet 2