EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-50-51-700-101 No. 5 Bearing Oil Nozzle, Filter, And Supply Tube - Do A Test For The Filter And Oil Jet, Testing-001
General
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
All test pressure referred to in the text are gage pressure.
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Hydraulic pressure testing rig | LOCAL | Hydraulic pressure testing rig |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 11-001 AVIATION KEROSENE | LOCAL | CoMat 11-001 |
Spares
NONESafety Requirements
NONEProcedure
Fit a suitable cover to the tube to be tested.
Connect the hydraulic pressure test rig to the tube adapter.
Open the bleed valve and apply a minimal hydraulic pressure to bleed the air from the tube. Close the bleed valve when you see a fluid flow free of air.
Gradually apply a hydraulic pressure as specified in Step
Maintain the pressure for a minimum of two minutes and examine the tube for signs of leakage, particularly at any swaged, brazed, welded or repaired areas.
Isolate the hydraulic supply, release the pressure and remove the test equipment from the tube.
SUBTASK 72-50-51-780-051 Hydraulic Pressure Test

WARNING
MAKE SURE THE SAFETY GUARDS ARE IN POSITION AROUND THE TUBE WHEN YOU APPLY THE HYDRAULIC PRESSURE.Clean the oil jet. Refer to Cleaning-000 TASK 72-50-51-100-100.
SUBTASK 72-50-51-110-051 Clean the Tubes