Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-61-49-100-101 Gearbox Breather Outlet Oil Duct - Clean, Cleaning-001
General
This TASK gives the procedure to clean the gearbox breather outlet duct (01- 010).
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
NOTE
References
Refer to the SPM for data on these items.
Cleaning Policy and Methods, refer to SPM TASK 70-10-00-100-501.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-076 METHYL ETHYL KETONE | LOCAL | CoMat 01-076 | ||
| CoMat 02-004 PAINT BRUSH | LOCAL | CoMat 02-004 | ||
| CoMat 02-099 LINT-FREE CLOTH | LOCAL | CoMat 02-099 |
Spares
NONESafety Requirements
NONEProcedure

WARNING
PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK WHEN YOU USE THIS CLEANING AGENT. DO NOT GET THE CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. USE THE CLEANING AGENT IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPORS. IF YOU GET THE CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IT YOUR SKIN OR EYES BECOME IRRITATED.
WARNING
BE CAREFUL WHEN YOU USE COMPRESSED AIR. PUT ON PROTECTIVE CLOTHING AND GOGGLES. MAKE SURE THAT ALL PERSONS ARE AT A SAFE DISTANCE.Remove any adhesive marking tape from the duct.
Flush the duct with cleaning agent.
Clean the internal surface of the duct.
Wipe the external surface of the duct.
Make sure all dirt and unwanted material is removed from the ends of the duct. Do not touch the seal faces after cleaning.
Clean the end fittings of the duct.
Use clean dry compressed air.
Remove the cleaning agent and make the duct dry.
SUBTASK 72-61-49-110-051 Clean the Duct