TASK 73-13-41-100-401 Fuel Nozzle And Support Assembly - Related Parts - Clean The Brackets, Cleaning-001

DMC:V2500-A0-73-13-4100-00A-251A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 73-13-41-100-401 Fuel Nozzle And Support Assembly - Related Parts - Clean The Brackets, Cleaning-001

Effectivity

FIG/ITEM

PART NO.

01-120

2A1466

01-120

6A6559

01-120

6A7452

01-180

2A1436

01-180

6A6558

01-190

5W2082

01-340

2A1479

01-340

6A6557

01-400

2A1488

01-400

6A6556

01-400

6A7453

01-450

5W8379

General

This TASK gives the procedure to clean the brackets. For the other fuel nozzle parts, refer to Cleaning-000 (TASK 73-13-41-100-200).

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC.

References

Refer to the SPM for data on these items.

Cleaning Policy. Refer to SPM TASK 70-10-00-100-501.

Cleaning Methods. Refer to SPM TASK 70-10-00-100-501.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 73-13-41-110-053 Chemically Clean the Brackets

    2. Clean the brackets. Refer to SPM TASK 70-11-01-300-503.

      1. Dry

      2. Clean dry air blast.

Requirements After Job Completion

Follow-On Conditions

NONE