DMC:V2500-A0-75-24-4900-00A-830A-CIssue No:002.00Issue Date:2019-11-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 75-24-49-550-101 LPT ACC Air Ducts And Tubes - Put The ACC Ducts And Tubes Into Storage, Storage-001
General
NOTE
Special tools are identified in the procedure by the tool
primary number.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| IAE 1M14084 Support fixture | 0AM53 | IAE 1M14084 | 1 |
Consumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Refer to Figure.
Install the upper manifold to the IAE 1M14084 Support fixture 1 off.
Safety the cooling air duct to the IAE 1M14084 Support fixture with the swing bolt and the two screws. Make sure that the tube ends are in their holes.
SUBTASK 75-24-49-440-051 Install the Upper Cooling Air Manifold to the Support Fixture
Refer to Figure.
Install the lower manifold to the IAE 1M14084 Support fixture 1 off.
Safety the cooling air duct to the IAE 1M14084 Support fixture with the swing bolt and the two screws. Make sure that the tube ends are in their holes.
SUBTASK 75-24-49-440-052 Install the Lower Cooling Air Manifold to the Support Fixture
Put the upper and lower cooling air manifolds and their IAE 1M14084 Support fixture in to storage.
SUBTASK 75-24-49-550-051 Put the Cooling Air Manifolds in to Storage
Figure: Install the Cooling Air Manifold to the Support Fixture
Install the Cooling Air Manifold to the Support Fixture