TASK 75-24-52-100-401 Active Clearance Control (ACC) Actuator - Related Parts - Clean The Actuator Front Bracket, Cleaning-001

DMC:V2500-A0-75-24-5200-00A-251A-C|Issue No:001.00|Issue Date:2014-05-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 75-24-52-100-401 Active Clearance Control (ACC) Actuator - Related Parts - Clean The Actuator Front Bracket, Cleaning-001

Effectivity

FIG/ITEM

PART NO.

01-170

5W2065

01-170

6A4572

General

This TASK gives the procedure to clean the actuator front bracket. For the other ACC actuator parts, refer to Cleaning-000 TASK 75-24-52-100-400.

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variant refer to the IPC.

References

Refer to the SPM for data on these items.

Cleaning Policy and Methods, SPM TASK 70-10-00-100-501.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 75-24-52-110-051-001 Chemically Clean the Actuator Front Bracket

    2. Clean the actuator front bracket. Refer to SPM TASK 70-11-01-300-503.

      1. Dry

      2. Clean dry air blast.

    1. SUBTASK 75-24-52-110-051-002 Chemically Clean the Actuator Front Bracket

      1. Clean the actuator front bracket. Refer to SPM TASK 70-11-03-300-503.

      2. Mild clean.

Requirements After Job Completion

Follow-On Conditions

NONE