TASK 75-32-52-100-102 HPC Stage 7 Bleed Outlet Duct Silencer - Clean, Cleaning-002

DMC:V2500-A0-75-32-5202-00A-251A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 75-32-52-100-102 HPC Stage 7 Bleed Outlet Duct Silencer - Clean, Cleaning-002

Effectivity

FIG/ITEM

PART NO.

01-060

6A1497

01-060

6A6533

01-250

6A2092

01-250

6A6535

01-250

6A8338

General

This TASK gives the procedure to clean the stage 7 bleed outlet duct silencer.

The practices and processes referred to in the procedure by the TASK number are in the SPM.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used.

NOTE

Consumable materials are given in the related SPM TASK

Reference

Refer to the SPM for data on these items

Cleaning Policy and Methods, SPM TASK 70-10-00-100-501.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 75-32-52-110-052-002 Clean the Silencer

      1. Clean the silencer, Refer to SPM TASK 70-11-03-300-503.

      2. Mild clean

Requirements After Job Completion

Follow-On Conditions

NONE