EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 78-32-47-700-301 Left C-Duct Electrical Harness - Test The Harness, Testing-001
General
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Megger | LOCAL | Megger | 250 volts DC or equivalent | |
| Lamp and battery teter | LOCAL | Lamp and battery tester | 4.5 volts DC |
Consumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Refer to Table.
SUBTASK 78-32-47-750-001 Do the Test to Find the Insulation Resistance Value of the Left C-Duct Electrical Harness
Refer to Table.
Connect the Lamp and battery teter - 4.5 volts DC to each end of the cable circuit.
Accept cable circuits where the test lamp comes on.
Reject all circuits where the test lamp does not come on.
Reject the harness if the light does not come on which shows no continuity.
SUBTASK 78-32-47-750-051 Do a Continuity Test on the Left C-Duct Electrical Harness
NOTE
Various methods can be used for continuity testing but in all cases the maximum voltage allowed is 24 volts DC.
Connector | Contact to | Connector | Contact |
|---|---|---|---|
901J | 1 | 905P | A |
901J | 2 | 905P | C |
901J | 3 | 905P | B |
901J | 4 | 903P | 1 |
901J | 5 | 903P | 2 |
901J | 6 | 903P | 3 |
901J | 7 | 903P | 4 |