TASK 72-00-00-050-001-B00 Engine General - Remove The Magnetic Chip Detectors (MCD) Probes, Removal-001

DMC:V2500-A5-72-00-0000-00C-520A-B|Issue No:001.00|Issue Date:2014-05-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

V2500-A5

Common Information

TASK 72-00-00-050-001-B00 Engine General - Remove The Magnetic Chip Detectors (MCD) Probes, Removal-001

General

Discard all rubber sealing rings removed in this procedure.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 72-00-00-050-062 Remove the Master MCD Probe at Position 1 (Pre SBE 70-0628, SBE 70-0628, Pre SBE 79-0042 and SBE 79-0042)

    2. Refer to Figure and Figure.

    3. Push the Master MCD probe in to its housing and turn it counterclockwise. Pull and remove the Master MCD probe.

    4. Remove and discard the sealing ring.

    1. SUBTASK 72-00-00-050-063 Remove the Remaining MCD Probes

    2. Refer to Figure and Figure.

    3. Do steps given in Step for the MCD probes at positions 2 thru 7.

  1. Figure: Pre SBE 70-0628: Remove the MCD Probes

    Sheet 1

    Legend
    Pre SBE 70-0628: Remove the MCD Probes

    Sheet 1

    Close

    Figure: SBE 70-0628, Pre SBE 79-0042 and SBE 79-0042 Remove the MCD Probes

    Sheet 2

    Legend
    SBE 70-0628, Pre SBE 79-0042 and SBE 79-0042 Remove the MCD Probes

    Sheet 2

    Close

Requirements After Job Completion

Follow-On Conditions

NONE