TASK 70-11-51-100-501 Make-Up Of The Solution For Demineralized Water Washing

DMC:V2500-00-70-11-51-00A-081A-D|Issue No:001.00|Issue Date:2013-03-20

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 70-11-51-100-501 Make-Up Of The Solution For Demineralized Water Washing

NOTE

To identify the consumable materials refer to the PCI.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NameManufacturerPart Number / IdentificationQuantityRemark
Stainless steel tankLOCALStainless steel tank
Demineralization plantLOCALDemineralization plant
Conductivity meterLOCALConductivity meter

(Schott-Gerard CG857, or Jenway 4070, or alternative)

Consumables, Materials and Expendables

NameManufacturerPart Number / IdentificationQuantityRemark
CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATERLOCALCoMat 01-201

Spares

NONE

Safety Requirements

WARNING

IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURERS MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.

Procedure

    1. SUBTASK 70-11-51-100-001 Make-up of the Demineralized Water

    2. The demineralized water shall be used directly from the demineralization plant and controlled as specified in the SPM TASK 70-11-51-200-502.

Requirements After Job Completion

Follow-On Conditions

NONE
Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Manufacturer Code:LOCAL
Supply Number:CoMat 01-201
Type:sp01
Supply Short Name:CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER
Supply Name:CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER
Specification Groups:
Doc NumberType
DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATERTHAT HAS 50,000 ohm‐cm MINIMUM ELECTRICAL RESISTIVITY OR 20 microsiemens/cm MAXIMUM ELECTRICAL CONDUCTIVITY, AND pH 5.0- 8.0.
Suppliers:
ManufacturerRemarks
LOCAL
06637
Manufacturer Code:LOCAL
Tool Number:Conductivity meter
Tool Name:Conductivity meter
Manufacturer Code:LOCAL
Tool Number:Demineralization plant
Tool Name:Demineralization plant
Manufacturer Code:LOCAL
Tool Number:Stainless steel tank
Tool Name:Stainless steel tank