Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-33-06-200-502 Control Of The Solutions Used For Stripping And Plating Of Nickel On Stainless Steel, Cobalt And Nickel Base Alloys
Test and Control of the 20 Percent Hydrochloric Acid Solution (Solution Code 27) | ||
Test and Control of the 50 Percent Nitric Acid Solution (Solution Code 28) | ||
Test and Control of the Nickel Strike Solution (Solution Code 30) | ||
Test and Control of the 100 Percent Inhibited Hydrochloric Acid Solution (Solution Code 31) | ||
Test and Control of the Titanium Etching Solution (Solution Code 32) | ||
Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33) | ||
Test and Control of the 65 Percent Hydrochloric Acid Solution (Solution Code 36) | ||
Test and Control of the Sulfuric-Hydrochloric Acid Solution (Solution Code 37) | ||
Test and Control of the Heavy Duty, Alkali Cleaner Solution (Solution Code 39) | ||
Test and Control of the Acid Salt Solution (Solution Code 46) | ||
Test and Control of the Alkali Cleaner Solution (Medium Duty)(Solution Code 47) | ||
Test and Control of the Alkali Smut Removal Solution (Solution Code 48) | ||
Test and Control of the Descaling Solution (Solution Code 50) | ||
Test and Control of Nickel Strip Solution (Cyanide)(Solution Code 54) | ||
Test and Control of the Soft Nickel Plating Solution (Sulfamate)(Solution Code 55) | ||
Test and Control of the Strip Solution (Cyanide)(Solution Code 56) | ||
Test and Control of the Nickel Strip Solution (Noncyanide)(for Silver or Copper Alloy Brazed Parts)(Solution Code 57) | ||
Test and Control of the Alkali Cleaner Solution (Heavy Duty, Phosphate-free) (Solution Code 58) | ||
Test and Control of the Nickel Strip Solution (Noncyanide)(Solution Code 59) | ||
Test and Control of the Nickel Strip Solution (Cyanide)(Solution Code 60) | ||
Test and Control of the Nickel Strip Solution (Noncyanide)(for Silver Alloy Brazed Parts)(Solution Code 61) | ||
Test and Control of the Nickel Sulfamate Strike Solution (Solution Code 66) | ||
Test and Control of the Nickel Strip Solution (for Silver or Copper Alloy Brazed Parts)(Solution Code 68) | ||
Test and Control of the Electrolytic Cleaner Solution (Heavy Duty, Phosphate-free and Cyanide-free)(Solution Code 137) | ||
Test and Control of the Alkali Smut Removal Solution (Solution Code 154) | ||
Test and Control of the Alkali Cleaner Solution (Heavy Duty, Phosphate-free)(Solution Code 156) | ||
Test and Control of the Heavy Duty Electrolytic Cleaner Solution (Without Phosphate or Cyanide)(Solution Code 165) | ||
Test and Control of the Alkali Cleaner Solution (Heavy Duty, Phosphate-free)(Solution Code 166) |
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
WARNING
Procedure
Refer to the P-1 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 for the test and control of Solution Code 27.
Refer to the Solution Index in TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 27.
SUBTASK 70-33-06-200-007 Test and Control of the 20 Percent Hydrochloric Acid Solution (Solution Code 27)
Refer to the P-1 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 for the test and control of Solution Code 28.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 28.
SUBTASK 70-33-06-200-008 Test and Control of the 50 Percent Nitric Acid Solution (Solution Code 28)
Refer to the P-17, P-100, and P-60 Test Methods in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-019, SUBTASK 70-11-47-180-033, and SUBTASK 70-11-47-180-027, respectively for the test and control of Solution Code 30.
Refer to the Solution Index in TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 30.
SUBTASK 70-33-06-200-009 Test and Control of the Nickel Strike Solution (Solution Code 30)
Refer to the P-1 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 for the test and control of Solution Code 31.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 31.
SUBTASK 70-33-06-200-010 Test and Control of the 100 Percent Inhibited Hydrochloric Acid Solution (Solution Code 31)
Refer to the P-33 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 for the test and control of Solution Code 32.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 32.
SUBTASK 70-33-06-200-011 Test and Control of the Titanium Etching Solution (Solution Code 32)
Refer to the P-33 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 for the test and control of Solution Code 33.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 33.
SUBTASK 70-33-06-200-012 Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33)
Refer to the P-1 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 for the test and control of Solution Code 36.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 36.
SUBTASK 70-33-06-200-013 Test and Control of the 65 Percent Hydrochloric Acid Solution (Solution Code 36)
Refer to the P-1 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 for the test and control of Solution Code 37.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 37.
SUBTASK 70-33-06-200-014 Test and Control of the Sulfuric-Hydrochloric Acid Solution (Solution Code 37)
Refer to the P-6 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-015 for the test and control of Solution Code 39.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 39.
SUBTASK 70-33-06-200-015 Test and Control of the Heavy Duty, Alkali Cleaner Solution (Solution Code 39)
Refer to the P-79 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-029 for the test and control of Solution Code 46.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 46.
SUBTASK 70-33-06-200-016 Test and Control of the Acid Salt Solution (Solution Code 46)
Refer to the P-6 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-015 for the test and control of Solution Code 47.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 47.
SUBTASK 70-33-06-200-017 Test and Control of the Alkali Cleaner Solution (Medium Duty)(Solution Code 47)
Refer to the P-36 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-024 for the test and control of Solution Code 48.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 48.
SUBTASK 70-33-06-200-018 Test and Control of the Alkali Smut Removal Solution (Solution Code 48)
Refer to the P-33 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 for the test and control of Solution Code 50.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 50.
SUBTASK 70-33-06-200-019 Test and Control of the Descaling Solution (Solution Code 50)
Refer to the P-18 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-020 for the test and control of Solution Code 54.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 54.
SUBTASK 70-33-06-200-020 Test and Control of Nickel Strip Solution (Cyanide) (Solution Code 54)
Refer to the P-17, P-100, P-82, and P-66 Test Methods in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-019, SUBTASK 70-11-47-180-033, SUBTASK 70-11-47-180-030, and SUBTASK 70-11-47-180-028, respectively for the test and control of Solution Code 55.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 55.
SUBTASK 70-33-06-200-021 Test and Control of the Soft Nickel Plating Solution (Sulfamate) (Solution Code 55)
Refer to the P-18 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-020 for the test and control of Solution Code 56.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 56.
SUBTASK 70-33-06-200-022 Test and Control of the Strip Solution (Cyanide) (Solution Code 56)
Refer to the P-90 and P-91 Test Methods in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-031 and SUBTASK 70-11-47-180-032, respectively for the test and control of Solution Code 57.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 57.
SUBTASK 70-33-06-200-023 Test and Control of the Nickel Strip Solution (Noncyanide) (for Silver or Copper Alloy Brazed Parts) (Solution Code 57)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 58.
SUBTASK 70-33-06-200-024 Test and Control of the Alkali Cleaner Solution (Heavy Duty, Phosphate-free) (Solution Code 58)
Refer to the P-18 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-020 for the test and control of Solution Code 60.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 60.
SUBTASK 70-33-06-200-026 Test and Control of the Nickel Strip Solution (Cyanide) (Solution Code 60)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test property or constituent and minimum test frequency for Solution Code 61.
SUBTASK 70-33-06-200-027 Test and Control of the Nickel Strip Solution (Noncyanide) (for Silver Alloy Brazed Parts) (Solution Code 61)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test methods, properties or constituents and minimum test frequencies for Solution Code 66.
SUBTASK 70-33-06-200-028 Test and Control of the Nickel Sulfamate Strike Solution (Solution Code 66)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test methods, properties or constituents and minimum test frequencies for Solution Code 68.
SUBTASK 70-33-06-200-029 Test and Control of the Nickel Strip Solution (for Silver or Copper Alloy Brazed Parts) (Solution Code 68)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test methods, properties or constituents and minimum test frequencies for Solution Code 137.
SUBTASK 70-33-06-200-030 Test and Control of the Electrolytic Cleaner Solution (Heavy Duty, Phosphate-free and Cyanide-free) (Solution Code 137)
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test methods, properties or constituents and minimum test frequencies for Solution Code 154.
SUBTASK 70-33-06-200-031 Test and Control of the Alkali Smut Removal Solution (Solution Code 154)
Refer to the P-36 Test Method in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-024 for the test and control of Solution Code 156.
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035 for the test properties or constituents and minimunm test frequencies for Solution Code 156.
SUBTASK 70-33-06-200-032 Test and Control of the Alkali Cleaner Solution (Heavy Duty, Phosphate-free) (Solution Code 156)