TASK 70-33-28-100-501 Make-Up Of The Solution For The Brush Nickel Plating Process

DMC:V2500-00-70-33-28-00A-081A-D|Issue No:001.00|Issue Date:2013-03-20

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 70-33-28-100-501 Make-Up Of The Solution For The Brush Nickel Plating Process

Table of Contents

Make-up of Alkali Smut Removal Solution (Solution Code 48)

Make-up of of the Alkali Cleaner Solution (Heavy Duty, Phosphate Free) (Solution Code 58)

Make-up of the Heavy Duty Electrolytic Cleaner Solution (Without Phosphate or Cyanide) (Solution Code 137)

Make-up of the Electrolytic Cleaner Solution (Cyanide-Type, Phosphate-Free) (Solution 154)

Make-up of the Heavy Duty Alkali Cleaner Solution (Solution 39)

Make-up of the Heavy Duty Alkali Cleaner Solution (Solution 47)

Make-up of the 55 Percent Nitric Acid Solution (Solution 28)

Make-up of the Nickel Strip Solution (Cyanide) (Solution 54)

Make-up of the Multiple Strip Solution (Cyanide) (Solution 56)

Make-up of the Nickel Strip Solution (Without Cyanide) (Solution 59)

Make-up of the Nickel Strip Solution (Cyanide) (Solution 60)

Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 57)

Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 61)

Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 68)

Make-up of the Electrolytic Cleaner Solution (Noncyanide) (Solution Code 165)

Safety Precautions

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

WARNING

IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.

Procedure

    1. SUBTASK 70-33-28-100-001 Make-up of Alkali Smut Removal Solution (Solution Code 48)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-048, for make-up of Solution Code 048.

    1. SUBTASK 70-33-28-100-002 Make-up of of the Alkali Cleaner Solution (Heavy Duty, Phosphate Free) (Solution Code 58)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-034 for the make-up of the Solution Code 058.

    1. SUBTASK 70-33-28-100-003 Make-up of the Heavy Duty Electrolytic Cleaner Solution (Without Phosphate or Cyanide) (Solution Code 137)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-062 for the make-up of Solution Code 137.

    1. SUBTASK 70-33-28-100-004 Make-up of the Electrolytic Cleaner Solution (Cyanide-Type, Phosphate-Free) (Solution 154)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-064 for the make-up of Solution Code 154.

    1. SUBTASK 70-33-28-100-005 Make-up of the Heavy Duty Alkali Cleaner Solution (Solution 39)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-015 for the make-up of Solution Code 39.

    1. SUBTASK 70-33-28-100-006 Make-up of the Heavy Duty Alkali Cleaner Solution (Solution 47)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-023 for the make-up of Solution Code 47.

    1. SUBTASK 70-33-28-100-007 Make-up of the 55 Percent Nitric Acid Solution (Solution 28)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-004 for the make-up of Solution Code 28.

    1. SUBTASK 70-33-28-100-008 Make-up of the 50 Percent Nitric Acid Solution (Solution 81)

    2. This subtask is deleted.

    1. SUBTASK 70-33-28-100-009 Make-up of the Nickel Strip Solution (Cyanide) (Solution 54)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-030 for the make-up of Solution Code 54.

    1. SUBTASK 70-33-28-100-010 Make-up of the Multiple Strip Solution (Cyanide) (Solution 56)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-032 for the make-up of Solution Code 56.

    1. SUBTASK 70-33-28-100-011 Make-up of the Nickel Strip Solution (Without Cyanide) (Solution 59)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-035 for the make-up of Solution Code 59.

    1. SUBTASK 70-33-28-100-012 Make-up of the Nickel Strip Solution (Cyanide) (Solution 60)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-036 for the make-up of Solution Code 60.

    1. SUBTASK 70-33-28-100-013 Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 57)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-033 for the make-up of Solution Code 57.

    1. SUBTASK 70-33-28-100-014 Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 61)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-037 for the make-up of Solution Code 61.

    1. SUBTASK 70-33-28-100-015 Make-up of the Nickel Strip Solution (Without Cyanide) for Silver or Copper Alloy Brazed Parts (Solution 68)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-044 for the make-up of Solution Code 68.

    1. SUBTASK 70-33-28-100-016 Make-up of the Electrolytic Cleaner Solution (Noncyanide) (Solution Code 165)

    2. Refer to the SPM TASK 70-33-27-330-501, SUBTASK 70-33-27-180-074 for the make-up of Solution Code 165.

Requirements After Job Completion

Follow-On Conditions

NONE