Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-33-76-300-503 The Procedure To Remove IAE 70-38-10 (PWA 73), IAE 70-38-29 (PWA 273) And IAE 70-38-23 (PWA 275) from PWA 1447 And 1455 Materials
NOTE
General
To identify the consumable materials, refer to the Consumable Materials Index.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 02-021 MASKING WAX COMPOUND | 59460 | CoMat 02-021 |
Spares
NONESafety Requirements
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
Procedure
Degrease the part. Refer to SPM TASK 70-11-03-300-503.
Dry grit blast the applicable areas. Refer to SPM TASK 70-12-09-120-501.
Wax mask with CoMat 02-021 MASKING WAX COMPOUND all the areas that are not to have PWA 73, PWA 273, and PWA 275 removed. Refer to SPM TASK 70-38-24-300-503.

CAUTION
IF PARTS ARE NOT SUFFICIENTLY MASKED, OVERSPRAY DAMAGE CAN OCCUR.Apply a mask or maskants to the part. Make sure the part is sufficiently masked to prevent overspray damage.
SUBTASK 70-33-76-300-001 Prepare the Parts
Put the parts fully into the nitric-phosphoric acid strip solution or the nitric acid stripping solution (refer to SPM TASK 70-33-76-100-501) for 60 minutes at a minimum temperature of 75 °F (24 °C).

CAUTION
DO NOT BLAST WAX MASKED AREAS.Wet abrasive blast the parts, as required. Refer to SPM TASK 70-12-06-120-501.
Do Step again but leave the parts in the solution for only five minutes.
Examine the parts. If any of the PWA 73, PWA 273 and PWA 275 has not been removed (it will be seen as dark gray smut) do Step again for 25 minutes. Shake the solution continuously.
Remove the wax masking. Refer to SPM TASK 70-38-24-300-503.
SUBTASK 70-33-76-300-002 Remove the PWA 73, PWA 273 and PWA 275

CAUTION
TO PREVENT LOCAL PITTING ON THE PART, THE SOLUTION MUST HAVE STRONG AGITATION (MOTION) WHILE THE PART IS IN THE SOLUTION.MAKE SURE THE WAX MASK IS NOT DAMAGED BEFORE YOU PUT THE PART IN THE SOLUTION.