TASK 70-33-90-200-502 Test And Control Of The Solutions To Strip IAE 53-5 Plasma Spray Chromium Carbide (Method M)

DMC:V2500-00-70-33-90-00A-300A-D|Issue No:001.00|Issue Date:2013-03-20

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 70-33-90-200-502 Test And Control Of The Solutions To Strip IAE 53-5 Plasma Spray Chromium Carbide (Method M)

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

WARNING

IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS. THESE INCLUDE INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.

Procedure

  1. SUBTASK 70-33-90-200-001 Test and Control of the Alkaline Permanganate Solution (Solution Code 2) - DELETED

    1. SUBTASK 70-33-90-200-002 Test and Control of the Nitric/Inhibited Phosphoric Acid Solution (Solution Code 118)

    2. There is no testing necessary for Solution Code 118.

    1. SUBTASK 70-33-90-200-003 Test and Control of the Caustic Potassium Permanganate Descaling Solution (Solution Code 1)

    2. Refer to the solution testing schedule in the SPM TASK 70-11-49-110-501, SUBTASK 70-11-49-180-003 for the stock loss determination of Solution Code 1.

    1. SUBTASK 70-33-90-200-004 Test and Control of the Alkaline Permanganate Solution (Solution Code 12A, 12B, 12C, and 12D)

    2. Refer to the solution testing schedule in the SPM TASK 70-11-49-110-501, SUBTASK 70-11-49-180-003 for the stock loss determination of Solution Code 12A, 12B, 12C, and 12D.

    1. SUBTASK 70-33-90-200-005 Test and Control of the Alkaline Permanganate Solution (Solution Code 140)

    2. Refer to the solution testing schedule in the SPM TASK 70-11-49-110-501, SUBTASK 70-11-49-180-003 for the stock loss determination of Solution Code 140.

    1. SUBTASK 70-33-90-200-006 Test and Control of the Alkaline Permanganate Solution (Solution Code 100)

    2. Refer to the solution testing schedule in the SPM TASK 70-11-49-110-501, SUBTASK 70-11-49-180-003 for the stock loss determination of Solution Code 100.

  2. SUBTASK 70-33-90-200-007 Test and Control of the Alkaline Permanganate Solution (Solution Code 101) - DELETED

    1. SUBTASK 70-33-90-200-008 Test and Control of the Alkaline Permanganate Solution (Solution Code 141)

    2. Refer to the solution testing schedule in the SPM TASK 70-11-49-110-501, SUBTASK 70-11-49-180-003 for the stock loss determination of Solution Code 141.

    1. SUBTASK 70-33-90-200-009 Test and Control of the Alkaline Permanganate Solution (Solution Code 161)

    2. There is no testing necessary for Solution Code 161.

    1. SUBTASK 70-33-90-200-010 Test and Control of the Alkaline Permanganate Solution (Solution Code 168)

    2. There is no testing necessary for Solution Code 168.

    1. SUBTASK 70-33-90-200-011 Test and Control of the Alkaline Permanganate Solution (Solution Code 162)

    2. There is no testing necessary for Solution Code 162.

Requirements After Job Completion

Follow-On Conditions

NONE