DMC:V2500-00-70-37-01-00A-634A-DIssue No:001.00Issue Date:2013-03-20
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-37-01-370-501 Stress-Relief Cycle 12A
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
WARNING
IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS. THESE CONTAIN INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS IN TO CONSIDERATION.
Procedure
NOTE
Cycle 12A increases and decreases the temperature gradually to keep to a minimum the distortion of parts in which sudden temperature changes can cause distortion.NOTE
If a repair task specifies to use Cycle 12 (Refer to the SPM TASK 70-37-29-370-501), then it is permitted to use Cycle 12A as an alternative to Cycle 12.NOTE
If a repair task specifies to use Cycle 12A, but does not specify to use Cycle 12 (Refer to the SPM TASK 70-37-29-370-501), then it is not permitted to use Cycle 12 as an alternative to Cycle 12A.Put the part in a cold oven. Air is a permitted atmosphere.
SUBTASK 70-37-01-370-001 Stress-Relief Cycle 12A