Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 30-21-49-300-003 Anti-Ice Ducts - Blend Repair Surface Damage, Repair-003 (VRS2858)
Effectivity
FIG/ITEM | PART NO. |
01-010 | 740-5172-505 |
01-050 | 740-5173-507 |
01-070 | 740-5151-513 |
01-070 | 745-5151-501 |
01-070 | 745-5151-503 |
01-070 | 740-5183-501 |
01-070 | 740-5183-503 |
02-100 | 740-5152-507 |
02-100 | 745-5152-501 |
02-100 | 745-5152-503 |
02-500 | 740-5153-507 |
02-500 | 745-5153-501 |
02-500 | 745-5153-503 |
General
This repair can be done on the Anti-Ice Ducts/Venturi during overhaul.
The practices and procedures referred to in the procedure by the TASK numbers are in the (SPM).
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Micrometer | LOCAL | Micrometer | 0.0 in. to 1.0 in. (0.0 mm to 25.4 mm) ball anvil type | |
| Micrometer | LOCAL | Micrometer | 1.0 in. to 2.0 in. (25.4 mm to 50.8 mm) ball anvil type | |
| Micrometer | LOCAL | Micrometer | 2.0 in. to 3.0 in. (50.8 mm to 76.2 mm) ball anvil type |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-076 METHYL ETHYL KETONE | LOCAL | CoMat 01-076 | ||
| CoMat 02-099 LINT-FREE CLOTH | LOCAL | CoMat 02-099 |
Spares
NONESafety Requirements
NONEProcedure
The repair area of the duct must measure a minimum dimension of 10 times the depth of damage.
Mark the repair area of the duct.
Use the applicable micrometer and record the diameter.
Measure the external diameter of the duct at the damaged area.
SUBTASK 30-21-49-220-071 Examine the Area of the Duct for Repair
Refer to SPM TASK 70-35-03-300-501.
Remove the damage.
SUBTASK 30-21-49-350-052 Repair the Area of Damage
Use the CoMat 01-076 METHYL ETHYL KETONE and the CoMat 02-099 LINT-FREE CLOTH.
Make the area clean with a clean piece of lint free cloth before the fluid dries.
Clean the repaired area.
SUBTASK 30-21-49-110-055 Clean the Repaired Area

WARNING
DO NOT GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GLOVES, GOGGLE AND A MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE GAS. IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR EYES FLUSH IT AWAY WITH WATER. GET MEDICAL AID IF YOUR SKIN OR EYES BECOME IRRITATED.Refer to Inspection-000 TASK 30-21-49-200-100.
Make sure that the repair area is smooth and has no scratches.
Make sure that the repaired area has no sudden changes in thickness.
Examine the repaired area.
Refer to Figure.
Use the applicable micrometer.
Make sure that the deepest area of the repair is measured.
Record the diameter.
Measure the external diameter of the duct at the repaired area.
Refer to Figure (Dimension X).
Compare the external diameter measurement (after the repair) with the measurement made before the repair.
The difference between them must be no more than 0.004 in. (0.102 mm).
If more than 0.004 in. (0.102 mm), discard the duct.
Calculate the wall thickness of the duct in the repaired area.
SUBTASK 30-21-49-220-072 Examine the Repaired Area
The repair area of the end fitting must measure a minimum of 10 times the depth of damage.
Mark the repair area of the end fitting.
Use the applicable micrometer and record this dimension.
Measure the thickness of the materials at the damaged area.
SUBTASK 30-21-49-220-073 Examine the Area of the End Fitting for Repair
Refer to SPM TASK 70-35-03-300-501.
Remove the damage.
SUBTASK 30-21-49-350-053 Repair the Area of Damage
Make the area clean with a clean piece of lint-free cloth before the fluid dries.
Use the CoMat 01-076 METHYL ETHYL KETONE and the CoMat 02-099 LINT-FREE CLOTH.
Clean the repaired area.
SUBTASK 30-21-49-110-056 Clean the Repaired Area

WARNING
DO NOT GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GLOVES, GOGGLES AND A MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE GAS. IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL AID IF YOUR SKIN OR EYES BECOME IRRITATED.Refer to Inspection-000 TASK 30-21-49-200-100.
Make sure that the repair area is smooth and has no scratches.
Make sure that the repaired area has no sudden changes in thickness.
Examine the repaired area.
Make sure that the deepest area of the repair is measured. Record the thickness.
Measure the thickness of the material at the repaired area.
Refer to Figure (Dimension X).
Compare the thickness measurement (after the repair) with the measurement made before the repair.
The difference between the measurements must not be more than 0.010 in. (0.254 mm).
Discard any end fittings that are not in these limits.
Calculate the thickness of the end fitting in the repaired area.
SUBTASK 30-21-49-220-074 Examine the Repaired Area
Refer to TASK 30-21-49-700-001.
Do a pressure test on the repaired duct.
SUBTASK 30-21-49-780-055 Pressure Test the Repaired Duct
Refer to SPM TASK 70-09-00-400-501.
Mark the repair scheme number VRS2858 on the duct adjacent to the part number using the electro-etch method
SUBTASK 30-21-49-850-051 Put the Repair Scheme Number on the Duct/End Fitting
Figure: Anti-Ice Ducts Repair Area
Anti-Ice Ducts Repair Area

