DMC:V2500-A0-71-52-4300-01A-251A-CIssue No:001.00Issue Date:2014-05-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 71-52-43-100-402 EEC Core Harness And Voltage Divider Harness Assembly - Related Parts - Clean The EEC Harness Core Bracket, Cleaning-002
General
This TASK gives the procedure for the cleaning of the EEC harness-core bracket. For other EEC harness-core parts refer to Cleaning-000 TASK 71-52-43-100-400 and CLEANING-000 TASK 71-52-43-100-300.
Fig./item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig./item numbers are used. For the service bulletin alpha variants refer to the IPC.
The practices and processes referred to in the procedure by the TASK/SUBTASK numbers are in the SPM.
NOTE
The consumable materials are given in the related SPM TASK.
References
Refer to the SPM for data on these items:
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Aqueous clean.

WARNING
DO NOT GET CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.Clean the bracket. Refer to SPM TASK 70-11-03-300-503.
SUBTASK 71-52-43-110-053-001 Clean the EEC Harness-Core Bracket
Locally swab or wipe.

WARNING
DO NOT GET CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.Clean the bracket. Refer to SPM TASK 70-11-26-300-503.
SUBTASK 71-52-43-110-053-002 Clean the EEC Harness-Core Bracket