EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 71-52-45-100-301 Exhaust Gas Temperature (EGT) Wiring Harness - Clean The Harness, Cleaning-001 (PRE and POST SBE 77-0015)
Effectivity
FIG/ITEM | PART NO. | REMARKS |
01-005 | 2A1490 | PRE SBE 77-0015 |
01-005 | 2A4524 | POST SBE 77-0015 |
01-005 | 6A4720 | PRE SBE 77-0015 |
01-005 | 6A5878 | PRE SBE 77-0015 |
General
This TASK gives the procedure for the cleaning of the EGT Wiring harness (PRE and POST SBE 77-0015).
The practices and processes referred to in the procedure by the TASK/SUBTASK numbers are in SPM.
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
The consumable materials are given in the related SPM TASK.
References
Refer to General Cleaning, SPM TASK 70-10-00-100-501 for important cleaning information that supplements the TASKs.
When more than one TASK or SUBTASK is specified for a part, refer to General Cleaning, SPM TASK 70-10-00-100-501 for selection of the applicable cleaning TASK or SUBTASK.
Refer to General Cleaning, SPM TASK 70-11-00-110-501 for the TASK number given below.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Clean the contact points and wiring harness.
Solvent clean. Refer to SPM TASK 70-11-57-110-501.
SUBTASK 71-52-45-110-051 Chemically Clean the EGT Harness