TASK 72-32-60-100-001-B00 LPC Bleed Duct - Clean, Cleaning-001

DMC:V2500-A0-72-32-6001-00B-251A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-32-60-100-001-B00 LPC Bleed Duct - Clean, Cleaning-001

Effectivity

FIG/ITEM

PART NO.

01-250

5W2231

01-250

5W2268

01-250

5W2280

01-250

5W2318

01-250

5W2331

01-250

5W2332

General

This TASK gives the procedure for the cleaning of the LPC bleed duct. For the other booster stage bleed valve outlet case parts, refer to TASK 72-32-60-100-000 (CLEANING-000).

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.

References

Refer to the SPM for data on these items.

Cleaning Policy, SPM TASK 70-10-00-100-501

Cleaning Methods, SPM TASK 70-10-00-100-501

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 72-32-60-110-057 Chemically Clean the LPC Bleed Duct Assembly

    2. Clean the LPC bleed duct assembly. Refer to the SPM TASK 70-11-26-300-503

      1. Dry.

      2. Clean dry air blast.

Requirements After Job Completion

Follow-On Conditions

NONE