EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-41-33-300-012 HPC Variable Stator Vane Shroud Bushes - Repair Surface Damage By Material Removal, Repair-012 (VRS6275)
Effectivity
FIG/ITEM PART NO. | |
|---|---|
01-190 | 6A3497 |
01-190 | 6A7728 |
01-190 | 6B1137 |
02-190 | 6A3497 |
02-190 | 6A7728 |
02-190 | 6B1137 |
03-190 | 6A3497 |
03-190 | 6A7728 |
03-190 | 6B1137 |
04-190 | 6A3497 |
04-190 | 6A7728 |
04-190 | 6B1137 |
General
This repair must only be done when the instruction to do so is given in 72-41-33 INSPECTION/CHECK.
The practices and processes referred to in the procedure by the TASK/SUBTASK numbers are in the SPM.
Price and Availability
Refer to International Aero Engines
Related Repairs - None
NOTE
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Chemical cleaning equipment | LOCAL | Chemical cleaning equipment | ||
| Penetrant Crack Test Equipment | LOCAL | Penetrant crack test equipment | ||
| Standard workshop equipment | LOCAL | Standard workshop equipment | ||
| Workshop inspection equipment | LOCAL | Workshop inspection equipment |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 05-106 ABRASIVE STONE | K6835 | CoMat 05-106 | ||
| CoMat 05-111 EMERY POLISHING PAPER | 06565 | CoMat 05-111 | ||
| CoMat 05-112 EMERY POLISHING PAPER | LOCAL | CoMat 05-112 | ||
| CoMat 06-064 FLUORESCENT PENETRANT (WATER WASHABLE MEDIUM SENSITIVITY) | LOCAL | CoMat 06-064 |
Spares
NONESafety Requirements
NONEProcedure
Refer to the SPM TASK 70-23-02-230-501.
Use CoMat 06-064 FLUORESCENT PENETRANT (WATER WASHABLE MEDIUM SENSITIVITY) with penetrant crack test equipment.
No cracks are permitted.
Do a penetrant crack test.
SUBTASK 72-41-33-230-072 Do a Crack Test
Refer to Figure.
Refer to the SPM TASK 70-35-03-300-501.
The diameter of the repaired area must be 50 x D, where D is the maximum depth of material removed and must not be more than 0.005in. (0.13 mm.).
Remove area(s) of damage.
Refer to the SPM TASK 70-35-03-300-501.
Remove sharp corners.
Make sure damage marks are fully removed.
Make smooth.
Polish.
SUBTASK 72-41-33-350-076 Remove Damaged Areas
Refer to Figure.
SUBTASK 72-41-33-220-130 Examine the Repair
Refer to the SPM TASK 70-23-05-230-501.
Use CoMat 06-064 FLUORESCENT PENETRANT (WATER WASHABLE MEDIUM SENSITIVITY) with penetrant crack test equipment.
No cracks are permitted.
Do a local penetrant crack test of the repaired area(s).
SUBTASK 72-41-33-230-073 Do a Crack Test
Figure: Repair details and dimensions