TASK 72-50-10-200-002 LPT Counterbalance Weight - Examine, Inspection-002

DMC:V2500-A0-72-50-1081-00A-351A-C|Issue No:002.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-50-10-200-002 LPT Counterbalance Weight - Examine, Inspection-002

Effectivity

FIG/ITEM PART NO.

01-070

3A0708

General

This TASK gives the procedure for the inspection of the counterbalance weight.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC.

The policy that is necessary for inspection is given in the SPM TASK 70-20-00-200-501.

All the parts must be cleaned before any part is examined. Refer to TASK 72-50-10-100-000.

All parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.

The procedure for those parts which must have a crack test is given in Step. Do the crack test before the part is visually examined.

Do not discard any part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.

Parts which should be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a later date.

All parts must be examined to make sure that all the repairs have been completed satisfactorily.

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

References

Refer to the SPM for data on these items.

Definitions of Damage, TASK 70-02-02-350-501

Record and Control of the Lives of Parts, TASK 70-05-00-220-501

Inspection of Parts, TASK 70-20-00-200-501

Some data on these items is contained in this TASK. For more data on these items refer to the SPM.

Method of Testing for Crack Indications

Chemical Processes

Surface Protection

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NameManufacturerPart Number / IdentificationQuantityRemark
Dial gageLOCALDial gage
Dial indicatorLOCALDial indicator

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 72-50-10-230-052 Do a Crack Test on the Counterbalance Weight (Fluorescent Penetrant)

    2. Clean the part. Refer to TASK 72-50-10-100-000. Do the test for cracks on the parts that are identified below. Use the applicable penetrant procedure.

      1. Do the test for cracks on the part that is given below. Use the applicable penetrant procedure.

        PART IDENT TASK/SUBTASK

        Counterbalance weight

        1. Cracked

        2. Reject

    1. SUBTASK 72-50-10-220-070 Examine the Counterbalance Weight for Surface Defects

      1. Examine the surface for dents.

        1. Dented.

          1. No limits for the dents, if function or assembly are possible

          2. Accept

          1. Badly dented, function or assembly are not possible

          2. Reject

      1. Examine the surface for nicks. Use dial gage and dial indicator to measure the depth of nicks or pits.

        1. Nicked up to 0.010 in. (0.25 mm) in depth

        2. Accept

        1. More than in (1)

        2. Reject

Requirements After Job Completion

Follow-On Conditions

NONE
Change Type:

Editorial correction due to conversion

Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Link not Found
Manufacturer Code:LOCAL
Tool Number:Dial indicator