DMC:V2500-A0-73-12-4100-00A-251A-CIssue No:001.00Issue Date:2014-05-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 73-12-41-100-401 Fuel Pumps - Related Parts - Clean The Adapter Housing, Cleaning-001
General
This TASK gives the procedure to clean the adapter housing.
The practices and processes referred to in the procedure by the TASK numbers are in the SPM.
References
Refer to the SPM for data on these items.
Cleaning Policy and Methods, TASK 70-10-00-100-501.
Make-up of the Solutions to Solvent Clean, SPM TASK 70-11-26-100-501.
The Test and Control of the Solutions to Solvent Clean, SPM TASK 70-11-26-200-502.
The Procedure to Solvent Clean, SPM TASK 70-11-26-300-503.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Remove the soft dirt and dust. Refer to SPM TASK 70-11-26-300-503.
SUBTASK 73-12-41-110-052 Clean the Adapter Housing to Remove the Soft Dirt and Dust