EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 73-22-35-100-401 EEC Data Entry Plug - Related Parts - Clean The Data Entry Plug Assembly, Cleaning-001
General
This TASK gives the procedure to clean the data entry plug assembly.
The practices and processes referred to in the procedure by the TASK numbers are in the SPM.
Fig/item numbers in parentheses in the procedure agree with those used in the IPC.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-001 SOLVENT, DELETED | 0AM53 | CoMat 01-001 | ||
| CoMat 01-005 SOLVENT CLEANER | 72190 | CoMat 01-005 | ||
| CoMat 01-124 ISOPROPYL ALCOHOL | LOCAL | CoMat 01-124 | ||
| CoMat 02-174 COTTON SWABS | LOCAL | CoMat 02-174 | ||
| CoMat 02-175 BRUSH | LOCAL | CoMat 02-175 |
Spares
NONESafety Requirements
NONEProcedure
Clean the pins, jumpers and rubber insert of the connector assembly with CoMat 02-174 COTTON SWABS and CoMat 01-124 ISOPROPYL ALCOHOL.
Dry immediately with clean dry air at a maximum pressure of 30 psig (206.8 kPa).
Clean the external surface of the connector and the external and the internal surfaces of the backshell with CoMat 01-001 SOLVENT, DELETED and CoMat 02-175 BRUSH or clean by the procedure given in SPM TASK 70-11-26-300-503.
Dry with clean, dry air at a maximum pressure of 30 psig (206.8 kPa).
Clean the chain of the backshell with CoMat 01-005 SOLVENT CLEANER and a clean cloth.
Dry with clean, dry air at a maximum pressure of 30 psig (206.8 kPa).
SUBTASK 73-22-35-110-051 Clean the Data Entry Plug Assembly
NOTE
This procedure is for a disassembled data entry plug.