TASK 73-22-48-300-004 P2/T2 Sensor Air Tube - Repair Surface Damage, Repair-004 (VRS2902)

DMC:V2500-A0-73-22-4800-00A-649A-C|Issue No:001.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 73-22-48-300-004 P2/T2 Sensor Air Tube - Repair Surface Damage, Repair-004 (VRS2902)

Effectivity

FIG/ITEM

PART NO.

01-020

740-3124-501

Material Of Component

DESCRIPTION

SYMBOL

MATERIAL

P2/T2 Tube

RR

Stainless steel

General

This repair can be done on the P2/T2 tube during overhaul.

The practices and processes referred to in the procedure by the TASK numbers are in the (SPM).

NOTE

To identify the consumable materials refer to the (PCI).

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NameManufacturerPart Number / IdentificationQuantityRemark
MicrometerLOCALMicrometer

Ball anvil type

Consumables, Materials and Expendables

NameManufacturerPart Number / IdentificationQuantityRemark
CoMat 01-076 METHYL ETHYL KETONELOCALCoMat 01-076
CoMat 02-099 LINT-FREE CLOTHLOCALCoMat 02-099

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 73-22-48-220-057 Examine the Area for Repair

      1. Mark the repair area of the tube.

      2. The repair area of the tube must measure a minimum dimension of 10 times the depth of the damage.

      1. Measure the external diameter of the tube at the damaged area.

      2. Use the micrometer and record the diameter.

    1. SUBTASK 73-22-48-350-054 Repair the Area of Damage

      1. Remove the damage.

      2. Refer to SPM TASK 70-35-03-300-501.

    1. SUBTASK 73-22-48-110-054 Clean the Repaired Area

      1. WARNING

        DO NOT GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GLOVES, GOGGLES AND A MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE GAS. IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL AID IF YOUR SKIN OR EYES BECOME IRRITATED.

        Clean the repaired area.

      2. Use the CoMat 01-076 METHYL ETHYL KETONE and the CoMat 02-099 LINT-FREE CLOTHMake the area clean with a clean piece of lint-free cloth before the fluid dries.

    1. SUBTASK 73-22-48-220-058 Examine the Repaired Area

      1. Examine the repaired area.

      2. Make sure that the repaired area is smooth and has no scratches. Make sure that the repaired area has no sudden changes in thickness.

      1. Measure the external diameter of the tube at the repaired area

      2. Refer to Figure. Use the micrometer. Make sure that the deepest area of the repair is measured. Record the diameter.

      1. Calculate the wall thickness of the tube in the repaired area.

      2. Refer to Figure. (Dimension 'X').

      3. Compare the external diameter measurement (after the repair) with the measurement made before the repair.

      4. The difference between the measurements must not be more than 0.003 in. (0.0762 mm). If more than 0.003 in. (0.0762 mm) discard the tube.

    1. SUBTASK 73-22-48-780-055 Pressure Test the P2/T2 Tube

      1. Do a pressure test on the repaired tube.

      2. Refer to TASK 73-22-48-700-001.

    1. SUBTASK 73-22-48-850-053 Put the Repair Scheme Number on the Tube

      1. Mark the repair scheme number VRS2902 on the tube adjacent to the part number with the electro-etch method.

      2. Refer to SPM TASK 70-09-00-400-501.

  1. Figure: P2/T2 Tube Repair Area

    P2/T2 Tube Repair Area

Requirements After Job Completion

Follow-On Conditions

NONE
Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Manufacturer Code:LOCAL
Supply Number:CoMat 01-076
Type:sp01
Supply Short Name:CoMat 01-076 METHYL ETHYL KETONE
Supply Name:CoMat 01-076 METHYL ETHYL KETONE
Specification Groups:
Doc NumberType
METHYL ETHYL KETONE, TECHNICAL GRADE, CERTIFIED TO BSI BS 1940 OR ASTM D740, OR TT-M-261
Suppliers:
ManufacturerRemarks
LOCAL
Manufacturer Code:X222X
Supply Number:CoMat 02-099
Type:sp01
Supply Short Name:CoMat 02-099 LINT-FREE CLOTH
Supply Name:CoMat 02-099 LINT-FREE CLOTH
Specification Groups:
Doc NumberType
WHERE COMAT 02-099 IS SPECIFIED WITH NO SUFFIX, USE COMAT 02-099A OR COMAT 02-099B.
Suppliers:
ManufacturerRemarks
X222X
Manufacturer Code:LOCAL
Tool Number:Micrometer
Tool Name:Micrometer