DMC:V2500-A0-74-11-3800-02A-251A-CIssue No:002.00Issue Date:2014-05-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 74-11-38-100-404 Ignition Exciters - Related Parts - Clean The Bracket, Cleaning-004
General
This TASK gives the procedure to clean the bracket.
The practices and processes referred to in the procedure by the TASK number are in the SPM.
Fig/Item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/Item numbers are used.
Reference
Refer to the SPM for data on these items.
Cleaning policy, SPM TASK 70-10-00-100-501.
Cleaning Method, SPM TASK 70-10-00-100-501.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-031 ACETONE (CH3)2CO | LOCAL | CoMat 01-031 | ||
| CoMat 01-060 ACETONE (CH3)2CO | LOCAL | CoMat 01-060 | ||
| CoMat 01-076 METHYL ETHYL KETONE | LOCAL | CoMat 01-076 | ||
| CoMat 01-124 ISOPROPYL ALCOHOL | LOCAL | CoMat 01-124 |
Spares
NONESafety Requirements
NONEProcedure

WARNING
WHEN YOU USE COMAT 01-076 METHYLETHYLKETONE YOU MUST MAKE SURE THERE IS SUFFICIENT VENTILATION. YOU MUST USE THE CORRECT PROTECTIVE CLOTHING. YOU MUST NOT SMOKE. DO NOT PUT THE SOLVENT NEAR A SOURCE OF HEAT.Clean the bracket, Refer to SPM TASK 70-11-26-300-503.
Clean dry air blast.
Dry
SUBTASK 74-11-38-110-053 Chemically Clean the Bracket