TASK 75-24-51-100-402-B00 Active Clearance Control (ACC) Valve - Related Parts - Clean The Housing Assembly, Cleaning-002

DMC:V2500-A0-75-24-5100-01B-251A-C|Issue No:001.00|Issue Date:2014-05-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 75-24-51-100-402-B00 Active Clearance Control (ACC) Valve - Related Parts - Clean The Housing Assembly, Cleaning-002

Effectivity

FIG/ITEM

PART NO.

01-275

2A1512

01-275

2A1534

01-276

2A1587

01-276

2A3735

01-286

2A1588

01-286

2A3736

01-287

2A1589

01-287

2A3737

General

This TASK gives the procedure to clean the housing assembly. For the other active clearance control valve parts, refer to Cleaning-000 TASK 75-24-51-100-400.

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

NOTE

The consumable materials are given in the related SPM TASK.

Reference

Refer to General Cleaning, Section 70-10-00, in the Standard Practices Manual (SPM) for important cleaning information that supplements the TASKs

When more than one TASK or SUBTASK is specified for a part, refer to Section 70-10-00 in the SPM for selection of the applicable cleaning TASK or SUBTASK.

Refer to Section 70-11-00 in the SPM for the TASK number given below.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 75-24-51-110-052 Remove the Grease and Oil from the Housing Assembly

      1. Clean the housing assembly. Refer to SPM TASK 70-11-03-300-503 .

      2. Degrease Parts by Aqueous Cleaning.

    1. SUBTASK 75-24-51-110-075 Remove the Carbon and Scale from the Housing Assembly

      1. Remove the carbon and scale from the housing assembly. Refer to SPM TASK 70-11-13-300-503.

      2. Clean the Components (Long Soak for Cobalt and Nickel Based Alloys and Heat and Non-Corrosion Resistant Steels).

Requirements After Job Completion

Follow-On Conditions

NONE