DMC:V2500-A0-75-31-4200-00A-251A-CIssue No:002.00Issue Date:2021-08-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 75-31-42-100-401 LPC Bleed Master Actuator - Related Parts - Clean The LPC Bleed Master Actuator Bracket Assembly, Cleaning-001
General
This TASK gives the procedure to clean the bracket assembly. For the other LPC bleed master actuator parts, refer to Cleaning-000 TASK 75-31-42-100-400.
NOTE
To identify the consumable materials refer to the PCI.
References
Refer to the SPM for data on these items.
Cleaning Policy and Materials, SPM TASK 70-10-00-100-501.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-005 SOLVENT CLEANER | 72190 | CoMat 01-005 |
Spares
NONESafety Requirements
WARNING
DO NOT GET
CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING,
GOGGLES, AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA.
DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN
OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR
SKIN OR EYES BECOME IRRITATED.
Procedure
Do not immerse, use a soft bristle brush or swab.
Remove the soft dirt and dust. Refer to SPM TASK 70-11-26-300-503.
Use clean dry air blast.
Dry
SUBTASK 75-31-42-110-051-001 Chemically Clean the Bracket Assembly
Mild clean.
Clean the bracket. Refer to SPM TASK 70-11-03-300-503.
SUBTASK 75-31-42-110-051-002 Chemically Clean the Bracket Assembly