Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 75-32-41-100-401 HPC Variable Stator Vane Actuator - Related Parts - Clean The Variable Stator Vane Actuator Brackets, Cleaning-001
General
This TASK gives the procedure for the cleaning of the variable stator vane actuator brackets. For other variable stator vane actuator parts, refer to Cleaning-000 TASK 75-32-41-100-400.
The practices and processes referred to in the procedure by the TASK/SUBTASK number are in the SPM.
Fig./item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig./item numbers are used. For the service bulletin alpha variants refer to the IPC.
NOTE
References
Refer to the SPM for data on these items:
Cleaning General Information, SPM TASK 70-10-00-100-501.
Chemical Cleaning, General Instructions, SPM TASK 70-11-00-110-501.
Make-up of the Solution to Vapor Degrease, SPM TASK 70-11-01-100-501.
The Test and Control of the Solutions Used to Vapor Degrease, SPM TASK 70-11-01-200-502
The Procedure to Vapor Degrease, SPM TASK 70-11-01-300-503.
Make-up of Solutions to Mild Clean Components (All Metals), SPM TASK 70-11-03-100-501.
The Test and Control of the Solutions to Mild Clean Components (All Metals), SPM TASK 70-11-03-200-502
The Procedure to Mild Clean Components (All Metals), SPM TASK 70-11-03-300-503
The Procedure to Solvent Clean (All Metals), SPM TASK 70-11-26-300-503.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Vapor degrease
Clean the bracket. Refer to SPM TASK 70-11-01-300-503.
SUBTASK 75-32-41-110-051-001 Chemically Clean the Brackets

WARNING
DO NOT GET CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.Mild clean
Clean the bracket. Refer to SPM TASK 70-11-03-300-503
SUBTASK 75-32-41-110-051-002 Chemically Clean the Brackets

WARNING
DO NOT GET CLEANING AGENT ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GOGGLES AND A FACE MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE VAPOR. IF YOU GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.BE CAREFUL WHEN YOU USE COMPRESSED AIR. PUT ON PROTECTIVE CLOTHING AND GOGGLES. MAKE SURE THAT ALL PERSONS ARE AT A SAFE DISTANCE.