Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
V2500-A1
Common Information
TASK 71-00-02-400-021-A00 (A1-PPBU) - Install The Thermal Anti-Ice (TAI) Duct Insulation, Installation-021
General
Fig/item numbers in parentheses in the procedure agree with those used in the EIPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the EIPC.
For all parts identified in a different Chapter/Section/Subject, the applicable Chapter/Section/Subject comes before the Fig/item number.
Lubricate all the bolt shanks given in this procedure with CoMat 10-073 SYNTHETIC GREASE, MoDISULFIDE, Mo disulphide. Lubricate all the bolt holes with CoMat 10-072 ANTISEIZE COMPOUND (MoDISULFIDE), unless other lubricants are referred to in the procedure.
Transportation covers/blanks must be removed immediately before the installation of the components.
After assembly apply CoMat 07-038 AIR DRYING ENAMEL to any damaged surface protection, joint flanges and attach parts. Use the correct color of the air drying enamel. Refer to the SPM TASK 70-38-21-380-501.
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 07-038 AIR DRYING ENAMEL | K3504 | CoMat 07-038 | ||
| CoMat 10-072 ANTISEIZE COMPOUND (MoDISULFIDE) | K6835 | CoMat 10-072 | ||
| CoMat 10-073 SYNTHETIC GREASE, MoDISULFIDE | 0AM53 | CoMat 10-073 |
Spares
NONESafety Requirements
NONEProcedure
Refer to Figure.
Install the inner and outer pipe insulation halves ICE AND RAIN PROTECTION-ANTI-ICE DUCTS (30-21-49, 01-210) and ICE AND RAIN PROTECTION-ANTI-ICE DUCTS (30-21-49, 01-215) to the duct assembly ICE AND RAIN PROTECTION-ANTI-ICE DUCTS (30-21-49, 01-070). Attach the insulation to the duct assembly with the installed clamps.
Install the inner and outer venturi duct insulation halves ICE AND RAIN PROTECTION-ANTI-ICE DUCTS (30-21-49, 01-220) and ICE AND RAIN PROTECTION-ANTI-ICE DUCTS (30-21-49, 01-225) to the venturi duct. Attach the insulation halves to the venturi duct assembly with the installed clamps.
Install the TAI duct insulation.
SUBTASK 71-00-02-420-025 Install the Thermal Anti-Ice (TAI) Duct Insulation
Figure: Install Thermal Anti-Ice (TAI) Duct Insulation
Install Thermal Anti-Ice (TAI) Duct Insulation