DMC:V2500-00-70-11-53-00A-300A-DIssue No:002.00Issue Date:2017-11-01
Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-11-53-200-502 Test And Control Of The Aqueous Carbon Remover Solution
Introduction
This task specifies the tests necessary to control the aqueous carbon remover solution. Refer to the SPM TASK 70-11-48-110-501for the procedure to test the subsequent cleaning solutions.
NOTE
To identify the consumable material, refer to the PCI.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-582 AQUEOUS-BASED CARBON REMOVER | 71410 | CoMat 01-582 |
Spares
NONESafety Requirements
WARNING
IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS. THESE CONTAIN INFORMATION SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.
WARNING
REFER TO THE SPM TASK 70-11-47-110-501 FOR SPECIFIC PRECAUTIONS.
Procedure
There is no test procedure for Solution Code 191.
Throw away the solution when the cleaning can no longer be done in the time specified in the cleaning procedure.
SUBTASK 70-11-53-200-003 Test and Control of the Aqueous Carbon Remover (Solution Code 191)