Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 70-33-25-200-502 Test And Control Of The Solutions Used For The Electroless Nickel Plating Of Titanium Parts
Table of Contents
Test and Control of the 55 Percent Nitric Acid Solution - (Solution Code 28) | ||
Test and Control of the Alkali Cleaner (Medium Duty) Solution - (Solution Code 47) | ||
Test and Control of the Alkali Smut Removal Solution - (Solution Code 48) | ||
Test and Control of the 100 Percent Hydrochloric Acid Solution - (Solution Code 82) | ||
Test and Control of the Rochelle Salt Solution - (Solution Code 83) | ||
Test and Control of the Copper Sulfate Strike Solution - (Solution Code 84) | ||
Test and Control of the Electroless Nickel Plating Solution - (Solution Code 86) | ||
Test and Control of the Electroless Nickel Plating Solution - (Solution Code 87) | ||
Test and Control of the Distilled or Deionized Water | ||
Test and Control of the Hydrofluoric-Nitric Acid Solution (Solution Code 150) | ||
Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 151) | ||
Test and Control of the Hydrochloric-Hydrofluoric Acid Solution (Solution Code 152) | ||
Test and Control of the Electroless Nickel Plating Solution (Solution Code 155) | ||
Test and Control of the Alkali Smut Removal Solution (Solution Code 156) | ||
Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33) |
Safety Precautions
General
Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035, for the Property or Constituent, Minimum Frequency and Test Method, of each of the solution codes used.
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER | LOCAL | CoMat 01-201 |
Spares
NONESafety Requirements
WARNING
Procedure
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 - Test Procedure P-1, for the test and control of Solution Code 28.
SUBTASK 70-33-25-200-001 Test and Control of the 55 Percent Nitric Acid Solution - (Solution Code 28)
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-015 - Test Procedure P-6, for the test and control of Solution Code 47.
SUBTASK 70-33-25-200-002 Test and Control of the Alkali Cleaner (Medium Duty) Solution - (Solution Code 47)
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-024 - Test Procedure P-36, for the test and control of Solution Code 48.
SUBTASK 70-33-25-200-003 Test and Control of the Alkali Smut Removal Solution - (Solution Code 48)
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 - Test Procedure P-1, for the test and control of Solution Code 82.
SUBTASK 70-33-25-200-005 Test and Control of the 100 Percent Hydrochloric Acid Solution - (Solution Code 82)
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-016 - Test Procedure P-8, SUBTASK 70-11-47-180-017 - Test Procedure P-9 and SUBTASK 70-11-47-180-014 - Test Procedure P-4 respectively for the test and control of Solution Code 84.
SUBTASK 70-33-25-200-007 Test and Control of the Copper Sulfate Strike Solution - (Solution Code 84)
Refer to the SPM TASK 70-11-49-110-501, Fig. 70-11-49-990-004, for the test and control of the CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER.
SUBTASK 70-33-25-200-011 Test and Control of the Distilled or Deionized Water
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 150.
SUBTASK 70-33-25-200-012 Test and Control of the Hydrofluoric-Nitric Acid Solution (Solution Code 150)
Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 151.
SUBTASK 70-33-25-200-013 Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 151)
Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-035 for the test and control of Solution Code 155.
SUBTASK 70-33-25-200-016 Test and Control of the Electroless Nickel Plating Solution (Solution Code 155)
Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-024 Test Procedure P-36, for the test and control of Solution Code 156.
SUBTASK 70-33-25-200-017 Test and Control of the Alkali Smut Removal Solution (Solution Code 156)
Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 33.
SUBTASK 70-33-25-200-018 Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33)