TASK 70-33-25-200-502 Test And Control Of The Solutions Used For The Electroless Nickel Plating Of Titanium Parts

DMC:V2500-00-70-33-25-00A-300A-D|Issue No:001.00|Issue Date:2013-03-20

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 70-33-25-200-502 Test And Control Of The Solutions Used For The Electroless Nickel Plating Of Titanium Parts

Table of Contents

Test and Control of the 55 Percent Nitric Acid Solution - (Solution Code 28)

Test and Control of the Alkali Cleaner (Medium Duty) Solution - (Solution Code 47)

Test and Control of the Alkali Smut Removal Solution - (Solution Code 48)

Test and Control of the 100 Percent Hydrochloric Acid Solution - (Solution Code 82)

Test and Control of the Rochelle Salt Solution - (Solution Code 83)

Test and Control of the Copper Sulfate Strike Solution - (Solution Code 84)

Test and Control of the Electroless Nickel Plating Solution - (Solution Code 86)

Test and Control of the Electroless Nickel Plating Solution - (Solution Code 87)

Test and Control of the Distilled or Deionized Water

Test and Control of the Hydrofluoric-Nitric Acid Solution (Solution Code 150)

Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 151)

Test and Control of the Hydrochloric-Hydrofluoric Acid Solution (Solution Code 152)

Test and Control of the Electroless Nickel Plating Solution (Solution Code 155)

Test and Control of the Alkali Smut Removal Solution (Solution Code 156)

Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33)

Safety Precautions

General

Refer to the Solution Index in the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-035, for the Property or Constituent, Minimum Frequency and Test Method, of each of the solution codes used.

NOTE

To identify the consumable materials, refer to the PCI.

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NONE

Consumables, Materials and Expendables

NameManufacturerPart Number / IdentificationQuantityRemark
CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATERLOCALCoMat 01-201

Spares

NONE

Safety Requirements

WARNING

IT IS THE RESPONSIBILITY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS FOR CONSUMABLE MATERIALS INFORMATION. THESE CONTAIN SUCH AS, HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.

Procedure

    1. SUBTASK 70-33-25-200-001 Test and Control of the 55 Percent Nitric Acid Solution - (Solution Code 28)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 - Test Procedure P-1, for the test and control of Solution Code 28.

    1. SUBTASK 70-33-25-200-002 Test and Control of the Alkali Cleaner (Medium Duty) Solution - (Solution Code 47)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-015 - Test Procedure P-6, for the test and control of Solution Code 47.

    1. SUBTASK 70-33-25-200-003 Test and Control of the Alkali Smut Removal Solution - (Solution Code 48)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-024 - Test Procedure P-36, for the test and control of Solution Code 48.

    1. SUBTASK 70-33-25-200-004 Test and Control of the 50 Percent Nitric Acid Solution - (Solution Code 81)

    2. Deleted.

    1. SUBTASK 70-33-25-200-005 Test and Control of the 100 Percent Hydrochloric Acid Solution - (Solution Code 82)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-013 - Test Procedure P-1, for the test and control of Solution Code 82.

    1. SUBTASK 70-33-25-200-006 Test and Control of the Rochelle Salt Solution - (Solution Code 83)

    2. There is no P-Test Procedure, for the test and control of Solution Code 83.

    1. SUBTASK 70-33-25-200-007 Test and Control of the Copper Sulfate Strike Solution - (Solution Code 84)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-016 - Test Procedure P-8, SUBTASK 70-11-47-180-017 - Test Procedure P-9 and SUBTASK 70-11-47-180-014 - Test Procedure P-4 respectively for the test and control of Solution Code 84.

    1. SUBTASK 70-33-25-200-008 Test and Control of the Electroless Nickel Plating Solution - (Solution Code 85)

    2. Deleted.

    1. SUBTASK 70-33-25-200-009 Test and Control of the Electroless Nickel Plating Solution - (Solution Code 86)

    2. Refer to the manufacturer's instructions, for the test and control of Solution Code 86.

    1. SUBTASK 70-33-25-200-010 Test and Control of the Electroless Nickel Plating Solution - (Solution Code 87)

    2. Refer to the manufacturer's instructions, for the test and control of Solution Code 87.

    1. SUBTASK 70-33-25-200-011 Test and Control of the Distilled or Deionized Water

    2. Refer to the SPM TASK 70-11-49-110-501, Fig. 70-11-49-990-004, for the test and control of the CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER.

    1. SUBTASK 70-33-25-200-012 Test and Control of the Hydrofluoric-Nitric Acid Solution (Solution Code 150)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 150.

    1. SUBTASK 70-33-25-200-013 Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 151)

    2. Refer to the SPM TASK 70-11-47-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 151.

    1. SUBTASK 70-33-25-200-014 Test and Control of the Hydrochloric-Hydrofluoric Acid Solution (Solution Code 152)

    2. There is no P-Test Procedure for the test and control of Solution Code 152.

    1. SUBTASK 70-33-25-200-015 Test and Control of the Electroless Nickel Plating Solution (Solution Code 153)

    2. Deleted.

    1. SUBTASK 70-33-25-200-016 Test and Control of the Electroless Nickel Plating Solution (Solution Code 155)

    2. Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-035 for the test and control of Solution Code 155.

    1. SUBTASK 70-33-25-200-017 Test and Control of the Alkali Smut Removal Solution (Solution Code 156)

    2. Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-024 Test Procedure P-36, for the test and control of Solution Code 156.

    1. SUBTASK 70-33-25-200-018 Test and Control of the Nitric-Hydrofluoric Acid Solution (Solution Code 33)

    2. Refer to the SPM TASK 70-11-49-110-501, SUBTASK 70-11-47-180-023 Test Procedure P-33, for the test and control of Solution Code 33.

Requirements After Job Completion

Follow-On Conditions

NONE
Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Manufacturer Code:LOCAL
Supply Number:CoMat 01-201
Type:sp01
Supply Short Name:CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER
Supply Name:CoMat 01-201 DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATER
Specification Groups:
Doc NumberType
DISTILLED, DEIONIZED, DEMINERALIZED, OR REVERSE OSMOSIS (RO) WATERTHAT HAS 50,000 ohm‐cm MINIMUM ELECTRICAL RESISTIVITY OR 20 microsiemens/cm MAXIMUM ELECTRICAL CONDUCTIVITY, AND pH 5.0- 8.0.
Suppliers:
ManufacturerRemarks
LOCAL
06637