Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-32-85-300-017 Fan Case - Repair The Attrition Lining Down To The GRC Layer, Repair-017 (VRS1556)
Material of component
DESCRIPTION | SYMBOL | MATERIAL |
|---|---|---|
Casing | Titanium alloy | |
Attrition lining | Aluminum honeycomb | |
Attrition lining | Non-metallic honeycomb | |
Attrition lining | Glass reinforced composite | |
Attrition lining | Filling compound |
General
Price and availability - refer to IAE
This Repair scheme gives the procedure for repair of attrition lining by filling with filler and can be applied to the damage which does not get to the depth of the Glass Reinforced Composite (GRC) layer
The practices and processes referred to in the procedure by TASK number are in the SPM.
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Hand held pneumatic grinder | LOCAL | Hand held pneumatic grinder | ||
| Sealant gun | LOCAL | Sealant gun | Air powered | |
| Rotary files | LOCAL | Rotary files | ||
| Putty knife | LOCAL | Putty knife | ||
| Vacuum cleaner | LOCAL | Vacuum cleaner |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-076 METHYL ETHYL KETONE | LOCAL | CoMat 01-076 | ||
| CoMat 02-099 LINT-FREE CLOTH | LOCAL | CoMat 02-099 | ||
| CoMat 05-016 GARNET PAPER, 80-GRIT | LOCAL | CoMat 05-016 | ||
| CoMat 08-006 FILLER, TWO PACK | LOCAL | CoMat 08-006 |
Spares
NONESafety Requirements
NONEProcedure
Take care not to damage the GRC layer which is sandwiched between the two layers of honeycomb in this area.
Refer to Figure.

CAUTION
THE FAN CASE IS MADE FROM TITANIUM ALLOY AND IS THIN IN SOME AREAS. IF YOU HIT THE FAN CASE WITH A CHISEL OR SCRAPER YOU CAN MAKE IT UNSERVICEABLE.
CAUTION
YOU MUST ALWAYS TRY TO POINT THE CHISEL OR SHARP BLADE PARALLEL WITH THE SURFACE OF THE FAN CASE.
CAUTION
STOP MACHINING AS SOON AS THE FILES, CUTTERS OR MACHINING BITS ARE THROUGH THE LINING MATERIAL. USE A STOP-MACHINING OR SLEEVE OR OTHER PENETRATION LIMITING DEVICE TO PREVENT DAMAGE TO THE CASING MATERIAL.
CAUTION
DO NOT USE POWERED TOOLS WITH STEEL CHISEL OR SIMILAR BITS.
CAUTION
DO NOT OPERATE WITHOUT SAFETY GOGGLES AND OTHER GUARDS EQUIPMENT. FLYING PARTICLES CAN CAUSE INJURY.NOTE
Keep the material removal to the minimum necessary to remove damaged area.Remove loose and damaged material from repair area.
A hollow sound is indicative of suspect bond.
Remove any unsound material.
If damage has reached the GRC layer or below the GRC layer.
Repair, refer to VRS1557 TASK 72-32-85-300-018 (REPAIR-018).
Check security of panels adjacent to repair area.
SUBTASK 72-32-85-350-075 Remove Defective Area of Damage
Refer to the SPM TASK 70-11-26-300-503.

WARNING
ALWAYS MAKE SURE THERE IS SUFFICIENT VENTILATION IN THE WORK AREA. EYE PROTECTION MUST ALWAYS BE USED. DO NOT LET THE SOLVENT CLEANER OR ITS VAPOR TOUCH THE EYES OR SKIN. PROTECTIVE CLOTHING AND FACE MASK MUST ALWAYS BE USED. ALWAYS KEEP OPEN FLAMES AWAY FROM THE WORK AREA. IT IS THE RESPONSILIBILTY OF THE OPERATOR TO OBTAIN AND OBSERVE THE MANUFACTURERS MATERIAL SAFETY SHEETS FROM THE CONSUMABLE MATERIALS INFORMATION SUCH AS HAZARDOUS INGREDIENTS, PHYSICAL/CHEMICAL CHARACTERISTICS, FIRE, EXPLOSION, REACTIVITY, HEALTH HAZARD DATA, PRECAUTIONS FOR SAFE HANDLING, USE AND CONTROL MEASURES AND ALSO TO TAKE LOCAL REGULATIONS INTO CONSIDERATION.Fully remove any grease from the repair area except the blue filler surface.
SUBTASK 72-32-85-110-070 Remove the Grease from the Repair Area
Ref to the SPM TASK 70-36-02-360-501.
Measure out materials by weight.
SUBTASK 72-32-85-360-061 Prepare Filler Material
Refer to the SPM TASK 70-36-02-360-501.
Use air powered sealant gun or equivalent.
Make sure that the repair area is fully filled with no air pockets.
If the complete fan track is to be filled to the depth to the GRC layer, start at the bottom and work both sides. The filler will gradually set.
If any sagging is apparent, locally produced supports will be necessary.
Fill the filler slightly more than necessary level in the damaged area.
The cure times and temperatures are given in Figure.

CAUTION
THE MAXIMUM TEMPERATURE WHICH CAN BE USED TO CURE THE FILLER IS 176 DEG F (80 DEG C).Cure the filler.
Refer to Figure.

CAUTION
DO NOT OPERATE WITHOUT SAFETY GOGGLES AND OTHER GUARD EQUIPMENT. FLYING PARTICLES CAN CAUSE INJURY.NOTE
The minimum cure time is one hour.Blend the filler to the contors.
SUBTASK 72-32-85-350-076 Apply Filler Material
A Step is acceptable if less than 0.02 in. (0.5 mm).
If necessary do this TASK again.
Refer to Figure.
Examine the surface of repaired area.
SUBTASK 72-32-85-220-083 Examine the repair Area
Figure: Repair the attrition lining down to GRC layer (SBE 72-0103)
Repair the attrition lining down to GRC layer (SBE 72-0103)

Figure: Curing Chart of Filling Material (08-006)