Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-61-49-300-002 Gearbox Breather Outlet Oil Duct - Blend Repair Surface Damage, Repair-002 (VRS2893)
General
This repair can be done on the Gearbox breather duct during overhaul.
The practices and processes referred to in the procedure by the TASK numbers are in the (SPM).
NOTE
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Micrometer | LOCAL | Micrometer | ball anvil type |
Consumables, Materials and Expendables
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| CoMat 01-076 METHYL ETHYL KETONE | 00BB6 | CoMat 01-076 | ||
| CoMat 02-099 LINT-FREE CLOTH | X222X | CoMat 02-099 |
Spares
NONESafety Requirements
NONEProcedure
The repair of the duct must measure a minimum dimension of 10 times the depth of the damage.
Mark the repair area of the duct.
Use the Micrometer and record the diameter.
Measure the external diameter of the duct at the damaged area.
SUBTASK 72-61-49-220-052 Examine the Area for Repair
Refer to SPM TASK 70-35-03-300-501.
Remove the damage.
SUBTASK 72-61-49-350-053 Repair the Area of Damage
Use the CoMat 01-076 METHYL ETHYL KETONE and the CoMat 02-099 LINT-FREE CLOTH.
Make the area clean with a clean piece of lint-free cloth before the fluid dries.

WARNING
DO NOT GET THE CLEANING FLUID ON YOUR SKIN OR IN YOUR EYES. PUT ON PROTECTIVE CLOTHING, GLOVES, GOGGLES AND A MASK. USE THE FLUID IN A WELL VENTILATED AREA. DO NOT BREATHE THE GAS. IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR EYES, FLUSH IT AWAY WITH WATER. GET MEDICAL AID IF YOUR SKIN OR EYES BECOME IRRITATED.Clean the repaired area.
SUBTASK 72-61-49-110-052 Clean the Repaired Area
Refer to Inspection-000 TASK 72-61-49-200-100.
Make sure that the repaired area is smooth and has no scratches.
Make sure that the repaired area has no sudden changes in thickness.
Visually examine the repaired area.
Refer to Figure.
Make sure that the deepest area of the repair is measured.
Record the diameter.
Measure the external diameter of the duct at the repaired area.
Refer to Figure (Dimension 'X').
Compare the external diameter measurement (after the repair) with the measurement made before the repair.
For the ducts repaired on one side the difference between the measurements must be more than 0.010 in. (0.254 mm).
For the ducts repaired all around their circumference the difference between the measurements must be not more than 0.020 in. (0.508 mm).
Discard ducts that are not in these limits.
Calculate the wall thickness of the duct in the repaired area.
SUBTASK 72-61-49-220-053 Examine the Repaired Area
Refer to TASK 72-61-49-700-101.
Do a pressure test on the repaired duct.
SUBTASK 72-61-49-780-053 Pressure Test the Repaired Duct
Refer to SPM TASK 70-09-00-400-501.
Mark the repair scheme number VRS2893 on the duct adjacent to the part number with the electro-etch method.
SUBTASK 72-61-49-850-051 Put the Repair Scheme Number on the Duct
Figure: Gearbox Breather Duct Repair Area
Gearbox Breather Duct Repair Area