EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 75-32-52-200-102-A00 HPC Stage 7 Bleed Outlet Duct, Seal Assembly And Silencer Assemblies - Examine The HPC Stage 7 Bleed Outlet Duct Silencer Assembly, Inspection-002
General
Refer to Inspection-000 TASK 75-32-52-200-400 (75-32-52, Inspection-000, Page 801) for other related parts.
Fig/Item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/Item numbers are used. For the service bulletin alpha variants refer to the IPC.
The policy that is necessary for inspection is given in SPM 70-20-01-220-501.
All the parts must be visually examined for damage, corrosion and wear. Defects that are not identified in the procedure must be referred to International Aero Engines AG.
Do not discard a part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.
Parts which must be discarded can be held although no repair is available.
The repair of a discarded part could be shown to be necessary at a subsequent date.
All parts must be examined to make sure that all the repairs are completed satisfactorily.
The practices and processes referred to in the procedure by the TASK number are in the SPM.
References
Refer to the SPM for data on these items.
Definitions of Damage, SPM TASK 70-02-02-350-501.
Inspection of Parts, SPM TASK 70-21-00-220-501.
Some data on these items is contained in this TASK. For more data on these items refer to the SPM.
Procedure for crack tests.
Chemical processes.
Surface protection.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Clean the parts. Refer to Cleaning-000 TASK 75-32-52-100-100.
SUBTASK 75-32-52-230-052-001 Examine the Silencers for Cracks
Accept
In areas other than Step. Of smooth type and large area related to depth, which do not decrease the diameter more than ten percent in one location.
Accept
In areas other than.Step Of smooth type and small area, not more than 0.500 sq in. (322.58 sq mm) with a depth not more than 0.250 in. (6.35 mm).
Dented
SUBTASK 75-32-52-220-056 Examine the Surfaces of the Silencers
Reject
Galled
Reject
Scored
Reject
Burred
Bolt holes
SUBTASK 75-32-52-220-057 Examine the Mount Flanges of the Silencers