EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-32-91-200-002-B00 LPC Inlet Guide Vane (Stator) - Examine, Inspection-002
General
This TASK gives the procedure for the inspection of the LPC inlet guide vane
The policy that is necessary for inspection is given in the SPM TASK 70-20-00-200-501.
All the parts must be cleaned before any part is examined. Refer to the TASK 72-32-91-100-000 (CLEANING-000).
All the parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.
The procedure for those parts which must have a crack test is given in Step. Do the test before the part is visually examined.
Do not discard any part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.
Parts which should be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a later date.
All the parts must be examined to make sure that all the repairs have been completed satisfactorily.
The practices and processes referred to in the procedure by the TASK numbers are in the SPM.
References
Refer to the SPM for data on these items.
Definitions of Damage, SPM TASK 70-02-02-350-501
Inspection of Parts, SPM TASK 70-20-00-200-501
Some data on these items is contained in this TASK. For more data on these items refer to the SPM.
Method of Testing for Crack Indications
Chemical Processes
Surface Protection
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Clean the parts. Refer to TASK 72-32-91-100-000 (CLEANING-000).
SUBTASK 72-32-91-230-057 Examine the LPC Inlet Guide Vane Assembly (01-400) for Cracks
Refer to Figure.
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Nicked
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Dented
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013, (REPAIR-013)
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Cracked
Examine the leading edges at location 1.
SUBTASK 72-32-91-220-072 Examine the LPC Inlet Guide Vane Assembly (01-400) Leading Edges
Refer to Figure.
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Nicked
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Dented
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (72-32-91, REPAIR 013
Cracked
Examine the trailing edges at location 2.
SUBTASK 72-32-91-220-073 Examine the LPC Inlet Guide Vane Assembly (01-400) Trailing Edges
Refer to Figure.
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Nicked
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Dented
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Cracked
Examine the convex and concave airfoil surface at location 3.
SUBTASK 72-32-91-220-074 Examine the LPC Inlet Guide Vane Assembly (01-400) Convex and Concave Airfoil Surface
Refer to Figure.
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Galled
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Cracked
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Scored bolt holes
Repair, VRS1773 TASK 72-32-91-300-009 (REPAIR-009)
Nicked air passage
Examine the outer platform at location 4.
SUBTASK 72-32-91-220-075 Examine the LPC Inlet Guide Vane Assembly (01-400) Outer Platform
Refer to Figure.
Repair, VRS1775 TASK 72-32-91-300-011 (REPAIR-011)
Corrosion pitting
Repair, VRS1775 TASK 72-32-91-300-011 (REPAIR-011)
Scratched
Repair, VRS1775 TASK 72-32-91-300-011 (REPAIR-011)
Dented
Repair, VRS1775 TASK 72-32-91-300-011 (REPAIR-011)
Nicked
Repair, VRS1775 TASK 72-32-91-300-011 (REPAIR-011)
Rubbed on the lip front face
Examine the inner shroud ring at location 5.
SUBTASK 72-32-91-220-076 Examine the LPC Inlet Guide Vane Assembly (01-400) Inner Shroud Ring
Refer to Figure.
Repair, VRS1776 TASK 72-32-91-300-012 (REPAIR-012)
More than 0.039 in. (1.00 mm)
Seal fin rubs.
Repair, VRS1776 TASK 72-32-91-300-012 (REPAIR-012)
Torn
Repair, VRS1776 TASK 72-32-91-300-012 (REPAIR-012)
Disbonded
Examine the abradable seal at location 6.
SUBTASK 72-32-91-220-077 Examine the LPC Inlet Guide Vane Assembly (01-400) Abradable Seal
Refer to Figure.
Repair, VRS1774 TASK 72-32-91-300-010 (REPAIR-010) or VRS1799 TASK 72-32-91-300-013 (REPAIR-013)
Disbond
Examine the moulding rubber at location 7.
SUBTASK 72-32-91-220-078Examine the LPC Inlet Guide Vane Assembly (01-400) Moulding Rubber
Figure: Locations on the LPC inlet guide vane
Locations on the LPC inlet guide vane