EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 71-11-43-200-302 Air Intake Cowl Harness - Examine The P2T2 - 4010VC And 4013VC Cable Assembly, Inspection-002
Effectivity
FIG/ITEM | PART NO. |
01-500 | 740-3235-503 |
01-500 | 740-3235-505 |
01-500 | 740-3235-507 |
01-500 | 740-3235-509 |
01-500 | 740-3235-511 |
General
Fig/item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig/item numbers are used. For the service bulletin alpha variants refer to the IPC.
The policy that is necessary for inspection is given in the SPM TASK 70-20-01-200-501
All the parts must be cleaned before they are examined, refer to Cleaning-000 TASK 71-11-43-100-300.
All the parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.
A ** following repair referenced in this inspection indicates that the repair is not yet published in the current revision of the manual and the part must be rejected. Contact IAE for additional information concerning FAA approved repair date.
Do not discard any part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.
Parts which should be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a later date.
Reference
Refer to the SPM for data on these items.
Definitions of Damage, SPM TASK 70-02-02-350-501.
Inspection of Parts, SPM TASK 70-20-00-200-501.
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
VRS2979 (Repair-001) TASK 71-11-43-300-001.
Cracked
VRS2979 (Repair-001) TASK 71-11-43-300-001.
Broken
VRS2979 (Repair-001) TASK 71-11-43-300-001.
Pick-up
VRS2979 (Repair-001) TASK 71-11-43-300-001.
Crossed or stripped
Threads
Coupling nuts
VRS2986 (Repair-002) TASK 71-11-43-300-002.
Bent
VRS2986 (Repair-002) TASK 71-11-43-300-002.
Worn (do the check with a new socket)
Contact pins
VRS2986 (Repair-002) TASK 71-11-43-300-002.
Bent
VRS2986 (Repair-002) TASK 71-11-43-300-002.
Worn (do the check with a new pin)
Contact sockets
SUBTASK 71-11-43-220-054 Examine the Connectors
VRS2927 (Repair-003) TASK 71-11-43-300-003.
Burned
VRS2927 (Repair-003) TASK 71-11-43-300-003.
Frayed
VRS2927 (Repair-003) TASK 71-11-43-300-003.
Fused
VRS2927 (Repair-003) TASK 71-11-43-300-003.
Chafed
VRS2986 (Repair-002) TASK 71-11-43-300-002.
Crimp joints
Loose
SUBTASK 71-11-43-220-055 Examine the Cables
VRS2971 (Repair-004) TASK 71-11-43-300-004.
Chafed
VRS2971 (Repair-004) TASK 71-11-43-300-004.
Frayed
SUBTASK 71-11-43-220-056 Examine the Ties