TASK 72-50-21-200-006-A00 LPT Stage 3 Front Heat Shield - Examine, Inspection-006

DMC:V2500-A0-72-50-2131-00A-300A-C|Issue No:002.00|Issue Date:2013-11-01

Export Control

EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.

Copyright

© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).

Applicability

All

Common Information

TASK 72-50-21-200-006-A00 LPT Stage 3 Front Heat Shield - Examine, Inspection-006

Effectivity

FIG/ITEM

PART NO.

01-460

3A0143

General

This TASK gives the procedure for the inspection of the stage 3 front heatshield. For the other LP turbine case parts, refer to TASK 72-50-21-200-000.

Fig/item numbers in parentheses in the procedure agree with those used in the IPC.

The policy that is necessary for inspection is given in the SPM TASK 70-20-01-200-501.

All the parts must be cleaned before any part is examined. Refer to the SPM TASK 70-11-03-300-503.

All parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.

The procedure for those parts which must have a crack test is given in Step. Do the test before the part is visually examined.

A ** following repair referenced in this inspection indicates that the repair is not yet published in the current revision of the manual and the part must be rejected. Contact IAE for additional information concerning FAA approved repair date.

Do not discard any part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.

Parts which should be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a later date.

All parts must be examined to make sure that all the repairs have been completed satisfactorily.

The practices and processes referred to in the procedure by the TASK numbers are in the SPM.

References

Refer to the SPM for data on these items.

Definitions of Damage, TASK 70-02-02-350-501

Record and Control of the Lives of Parts, TASK 70-05-00-220-501

Inspection of Parts, TASK 70-20-01-200-501

Some data on these items is contained in this TASK. For more data on these items refer to the SPM.

Method of Testing for Crack Indications

Chemical Processes

Surface Protection

Preliminary Requirements

Pre-Conditions

NONE

Support Equipment

NameManufacturerPart Number / IdentificationQuantityRemark
Illuminated magnifier (portable)LOCALIlluminated magnifier (portable)
Dial caliperLOCALDial caliper

Consumables, Materials and Expendables

NONE

Spares

NONE

Safety Requirements

NONE

Procedure

    1. SUBTASK 72-50-21-220-069 General Instructions for the Inspection of the Stage 3 Front Heatshield (01-460)

    2. Before inspection, clean the stage 3 front heatshield. Refer to TASK 72-50-21-100-000.

    3. Use illuminated magnifier to examine the stage 3 front heatshield.

    1. SUBTASK 72-50-21-230-056 Examine the Stage 3 Front Heatshield (01-460) for Cracks

      1. Fluorescent penetrant examine for cracks. Refer to the SPM TASK 70-23-02-230-501.

        1. Cracked up to 0.300in. (7.6 mm) in length, minimum distance 2.000in. (50.8 mm) apart, use dial caliper

        2. Accept

        1. Cracked longer or closer than in (1)

        2. Repair, VRS4017 TASK 72-50-21-300-014

    1. SUBTASK 72-50-21-220-070 Examine the Surface of the Stage 3 Front Heatshield (01-460) for Damage

      1. Examine the surface of the stage 3 front heatshield for nicks.

        1. Any number, without break through or raised material

        2. Accept

        1. Nicks with raised material

        2. Repair, VRS4016 TASK 72-50-21-300-013

        1. Nicks with break through

        2. Repair, VRS4017 TASK 72-50-21-300-014

      1. Examine the surface of the stage 3 front heatshield for dents.

        1. Any number, without break through or raised material

        2. Accept

        1. Dents with raised material

        2. Repair, VRS4016 TASK 72-50-21-300-013

        1. Dents with break through

        2. Repair, VRS4017 TASK 72-50-21-300-014

      1. Examine the surface of the stage 3 front heatshield for buckling.

        1. Lightly buckled, not affect the assembly

        2. Accept

        1. Heavily buckled, affect the assembly

        2. Reject

Requirements After Job Completion

Follow-On Conditions

NONE
Change Type:

Editorial correction due to conversion

Manufacturer Code:LOCAL
Enterprise Name:LOCALLY SUPPLIED
Manufacturer Code:LOCAL
Tool Number:Dial caliper
Tool Name:Dial caliper
Manufacturer Code:LOCAL
Tool Number:Illuminated magnifier (portable)
Tool Name:Illuminated magnifier (portable)